background image

EN

10

Operating manual – turbo fan TFV 10 / TFV 20 / TFV 30

Technical annex

Technical data

Parameter

Value

Model

TFV 10

Air flow rate

Stage 1
Stage 2

310 m³/h
380 m³/h

Mains connection

1/N/PE ~ 230 V / 50 Hz / 0.5 A

Power input

0.09 kW

Stat. air pressure (freely
blowing)

max. 150 Pa

Protection type

IP22

Sound level (distance 3 m)

Stage 1
Stage 2

61.5 dB(A)
68.5 dB(A)

Dimensions (L x W x H)

250 x 310 x 270 (mm)

Weight

5 kg

Model

TFV 20

Air flow rate

Stage 1
Stage 2

850 m³/h
1,185 m³/h

Mains connection

1/N/PE ~ 230 V / 50 Hz /
2.15 A

Power input

0.49 kW

Stat. air pressure (freely
blowing)

max. 390 Pa

Protection type

IP22

Sound level (distance 3 m)

Stage 1
Stage 2

64 dB(A)
69 dB(A)

Dimensions (L x W x H)

343 x 335 x 355 (mm)

Weight

12 kg

Parameter

Value

Model

TFV 30

Air flow rate

Stage 1
Stage 2
Stage 3

1,600 m³/h
1,850 m³/h
2,200 m³/h

Mains connection

1/N/PE ~ 230 V / 50 Hz / 5.2 A

Power input

max. 0.85 kW

Stat. air pressure (freely
blowing)

max. 425 Pa

Protection type

IP22

Sound level (distance 3 m)

Stage 1
Stage 2
Stage 3

73.5 dB(A)
80.8 dB(A)
86.2 dB(A)

Dimensions (L x W x H)

440 x 440 x 440 (mm)

Weight

18.5 kg

Disposal

The icon with the crossed-out waste bin on waste

electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. For further return options provided by us please
refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.

Содержание TFV 20

Страница 1: ...TRT BA TFV10 TFV20 TFV30 TC 002 EN TFV 10 TFV 20 TFV 30 EN OPERATING MANUAL TURBO FAN ...

Страница 2: ...ry or death Caution This signal word indicates a hazard with a low risk level which if not avoided can result in minor or moderate injury Note This signal word indicates important information e g material damage but does not indicate hazards Info Information marked with this symbol helps you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates ...

Страница 3: ...ctric cables or the power connection are damaged The electrical connection must correspond to the specifications in chapter Technical data Insert the mains plug into a properly secured mains socket Observe the technical data when selecting extensions to the power cable Completely unroll the extension cable Avoid electrical overload Before carrying out maintenance care or repair work on the device ...

Страница 4: ... description The devices TFV 10 TFV 20 TFV 30 were designed for a very high air flow rate They may be used for drying carpets buildings or screed as well as for the ventilation of poorly accessible intermediate spaces Owing to the high air circulation the devices can also be used to control excessive humidity levels The fan is also very effective for the additional air circulation when heating lar...

Страница 5: ... fan stage selection 2 Operating hours counter 3 Transport handle 4 Air outlet 5 Skids 6 Air inlet 7 Cable holder TFV 20 1 11 8 4 3 6 5 7 No Designation 1 Switch for fan stage selection 3 Transport handle 4 Air outlet 5 Skids 6 Air inlet 7 Cable holder 8 Service power socket 11 Dual counter operating and kilowatt hours ...

Страница 6: ... Hold onto the mains plug while pulling the power cable out of the mains socket Do not use the power cable to drag the device After transporting the device observe the following Set up the device in an upright position after transport Storage Before storing the device observe the following When the device is not being used observe the following storage conditions dry and protected from frost and h...

Страница 7: ...al three way hose distributor Info Seal off unused connections by means of suitable sealing caps and possibly with hose clamps to prevent a decrease in the air flow rate Info The procedure of fitting a hose distributor is described below using the example of a three way hose distributor that is connected to the TFV 30 however it applies accordingly to the TFV 20 and a two way hose distributor 1 Op...

Страница 8: ...hoses for tight fit Start up Positioning Set the device up separately and in a stable position The device can be variably positioned in a way to allow an air discharge at an angle of 0 45 or 90 0 45 90 Connecting the power cable Insert the mains plug into a properly secured mains socket Operation Operating elements TFV 10 1 No Designation 1 Switch for fan stage selection ...

Страница 9: ...fan stage stage 1 LOW stage 2 MEDIUM stage 3 HIGH ð The device is switched on Dual counter TFV 20 and TFV 30 The devices TFV 20 TFV 30 are equipped with a dual counter 11 The operating hours are indicated in the upper section of the counter the kilowatt hours are displayed just below The kWh counter is certified according to MID The LED 10 is illuminated as soon as a current flow is established Us...

Страница 10: ...r service The fan is not running Check whether the device is switched on Check the power connection Check the power cable and mains plug for damages Check the on site fusing Note Wait for at least 3 minutes after maintenance and repair work Only then switch the device back on Your device still does not operate correctly after these checks Please contact the customer service If necessary bring the ...

Страница 11: ...30 V 50 Hz 5 2 A Power input max 0 85 kW Stat air pressure freely blowing max 425 Pa Protection type IP22 Sound level distance 3 m Stage 1 Stage 2 Stage 3 73 5 dB A 80 8 dB A 86 2 dB A Dimensions L x W x H 440 x 440 x 440 mm Weight 18 5 kg Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the hou...

Страница 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...