8
EN
fan heater TFC 1 E / TFC 2 E
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch the device off.
•
Remove the mains plug from the mains socket.
•
Allow the device to cool down completely.
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
Cleaning the housing
Warning of electrical voltage
Never immerse the device in water!
Clean the housing with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.
Technical annex
Technical data
Parameter
Value
Model
TFC 1 E / TFC 2 E
Heating capacity
500 W
Setting range
15 °C to 30 °C
Room size
10 m
2
/ 25 m
3
Mains connection
220-240 V, 50/60 Hz
Plug type
CEE 7/17
Protection class
II /
Dimensions
(depth x width x height)
110 x 130 x 202 (mm)
Minimum distance to walls or
other objects
A: top:
B: sides:
C: bottom:
D: front:
25 cm
25 cm
25 cm
50 cm
Weight
0.4 kg