Operating manual – PCPS 10-16V / PCPS 11-16V
Operation
Tips and notes on handling the cordless compressor
General information:
•
Keep the venting slots clear to prevent the motor from
overheating.
•
The device is not suitable for continuous operation. The
device must not be used in continuous operation for more
than 10 minutes.
•
Only use intact, flawless valve adapters.
Operating elements
PSI
BAR
34
38
35
36
37
No. Designation
Meaning
34
Indication of the
unit
Indicates whether the pressure is
measured/set in bar or psi.
35
Minus button
Reduces the value.
36
Power button
Switches the device on or off. Once the
device is switched on, the button
serves to switch over between the
units bar and psi.
37
Plus button
Increases the value.
38
Segment display Indicates the current measured
pressure value.
Indicates the target pressure value
during setting.
Setting the pressure
Info
Please note that the pressure gauge is not calibrated.
1. Press the on/off switch (7) or the power button (36) located
at the display.
ð
The previously set pressure value will be indicated on
the segment display (38) for approx. 2 s.
ð
Then, the current pressure measurement will be
indicated on the segment display (38). If no item is
connected to the compressed-air hose, this value
amounts to 0.
2. Press and hold the plus (37) or minus (35) button for
approx. 2 s.
ð
The segment display (38) flashes.
3. Use the plus (37) and minus (35) buttons to set the desired
pressure value.
4. Wait until the segment display (38) stops flashing.
ð
The desired pressure value is set.
ð
Now the current pressure value will again be indicated
on the segment display (38).
Changing the unit bar / psi
You can choose whether the pressure is to be indicated in bar or
psi.
ü
The device is switched on.
1. Press the power button (36) to switch over between the
units bar and psi.
Switching the cordless compressor on and off
Info
Please note that the pressure gauge is not calibrated.
Info
The compressor is only in operation when the display
is switched on.
1. Check whether the applied valve adapter and the set
pressure value are suitable for the intended application.
2. Press the on/off switch (7) or the power button (36) located
at the display.
ð
The previously set pressure value will be indicated on
the segment display (38) for approx. 2 s.
ð
Then, the current pressure measurement will be
indicated on the segment display (38). If no item is
connected to the compressed-air hose, this value
amounts to 0.
3. Connect the compressed-air hose to the item to be inflated
by means of the mounted valve adapter.
ð
The pressure of the connected item will be indicated on
the segment display (38).
4. Adjust the desired pressure value if required (see chapter
Setting the pressure).