Trotec LD6000 PTS Скачать руководство пользователя страница 2

 

A - 1

EN

Operating manual for LD6000 PTS

Table of contents

01 Safety   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . A-1
02 Intended use   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . A-1
03 Scope of delivery and overview   .  .  .  .  .  .  .  .  .  .  .  .  .  .  . A-1
04 Start-up and application    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . A-2
05 Acoustic leak detection   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . A-5
06 Pipe and pinpoint location   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . A-6
07 Troubleshooting   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . A-7
08 Application examples  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . A-8
09 Cleaning, storage and transport   .  .  .  .  .  .  .  .  .  .  .  .  .  .  . A-8
10 Technical data   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . A-9
The measuring device at hand was built according to cur-
rent state-of-the-art technology and fulfils valid European 
and national directives . This conformity has been tested and 
the corresponding declarations and documents are kept on 
file by the manufacturer . To keep this condition and ensure 
safe operation, as a user, you must observe the following 
safety instructions .

01 Safety

We accept no liability for damages caused by non- 
observance of this manual or unprofessional handling . Any  
warranty claims are voided in such cases!

Prior to using the LD6000 PTS, this operating  

manual is to be carefully read and observed in 

every particular. 

For reasons of safety and conformity (CE), any unauthor-
ised change made to the device construction or compo-
nents which are to be used with the measuring device are  
prohibited!
• The LD6000 PTS me only be used for drinking water  

systems . The user is responsible for any other kind of use .  
Once used in other media, reuse for drinking water is  
prohibited!

• Observe the storage and operating conditions!
• Before using the LD6000 PTS, always observe the 

 

disinfection instructions (see page A-4)!

• The system's maximum operating pressure is 16 bar!
• The maximum bending radius of the probe and the fibre 

optic cable is 120 mm (which corresponds to 90° for  
pipes with DN 50) . In order to avoid jamming or even  
cable break, the fibre optic cable is only to be pushed with 
utmost caution when frequenting bottlenecks .

• The only party responsible for determining measured  

results to be valid, drawing conclusions and deriving  
actions is the user! The correctness of the results 

 

presented is excluded from any liability or guarantee .  
Liability for damages which have been caused by utilising 
the presented measured results is strictly excluded .

02 Intended use

The LD6000 PTS and associated accessories serve the  
purpose of leak detection in drinking water pipelines .
The device may only be used for this intended use while 
complying with the specified technical data .

03 Scope of delivery and overview

3.1 LD6000 PTS tube probe

1 .  Galvanized steel pipe frame with aluminium reel
2 .  Polykat fibreglass with integrated stranded copper 

wires

3 .  Bluetooth transmitter with connection option for a  

frequency generator

4 .  Flexible sensor head with precision microphone
5 .  Pressure-resistant cable passage
6 .  Storage container with disinfectant
7 .  Mechanical metre counter for length measurement

1.

2.

3.

4.
7.

6.

5.

Содержание LD6000 PTS

Страница 1: ...OPERATING MANUAL ACOUSTIC TUBE PROBE EN TRT BA LD6000PTS HS 003 EN LD6000 PTS...

Страница 2: ...in other media reuse for drinking water is prohibited Observe the storage and operating conditions Before using the LD6000 PTS always observe the disinfection instructions see page A 4 The system s m...

Страница 3: ...o pairing mode search mode If the transmitter unit is switched on and a Bluetooth connection is established briefly pressing the button activates the mute function muting If the MUTE LED is illuminate...

Страница 4: ...mode search mode Press the Multi func tion button for 6 s while switched off All level LEDs light up Bluetooth LED flashes Bluetooth setting Control LED display Establishing connection Waiting for th...

Страница 5: ...fibre optic cable into the pipeline it is continuously pulled through the disinfectant solution No specific application time is required during insertion The agent is pH neutral and after use can be...

Страница 6: ...x 30 50 cm At the end of each step the probe should be allowed to come to a rest in order to record the sound in the probe s environment 5 1 Using the Bluetooth headphones LD6000 PTS In the case of le...

Страница 7: ...where you detected the maximum level Then connect the frequency generator of your locating device to the LD6000 PTS Generally true for all frequency generators of locating devices Probe detection Whe...

Страница 8: ...D6000 PTS maximum reach 10 m Bring the devices back into the transmission range Batteries of the LD6000 PTS headphones Bluetooth receiver or speaker optionally available are too low Change the battery...

Страница 9: ...pter for hydrant by means of a GEKA coupling Connect the cable passage Fully open the hydrant Insert the probe 8 5 Insertion via tapping saddle Tap pipeline via a 45 tapping saddle Fix GEKA coupling t...

Страница 10: ...cation mute function muting 2 x 9 mm banana plug sockets receiver Bluetooth receiver for LD6000 combination detector o integrated Li ion battery o operating hours approx 6 h o Bluetooth 2 0 class 2 fr...

Отзывы: