EN
11
oil heater IDS 20 D / IDS 30 D
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Note
Damage to the device due to overheating!
Never switch off the device by pulling the mains plug.
This may lead to overheating!
Switch off the device properly. Only pull the mains plug
once the fan motor has stopped completely.
Switch-off in continuous operation mode
1. Switch off the device by setting the selector switch (16) or
on/off switch (13) to position
0
.
ð
The selector switch (16) or on/off switch (13) is no
longer illuminated.
2. Wait until the fan motor has come to a complete standstill.
3. Secure the device against inadvertent switch-on by pulling
the mains plug.
4. Allow the device to cool down completely.
Available accessories
Warning
Only use accessories and additional equipment
specified in the instructions.
Using insertion tools or accessories other than those
specified in the instructions may cause a risk of injury.
Accessories
Article number
Thermostat with 10 m cable
(IDS 30 D only)
6.100.007.016
Tank liquid level indication
6.100.006.160
Filler neck oil filter
6.100.006.161
Errors and faults
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
Warning
Risk of injury due to improper repair!
Never try to make any modifications or repairs on the
device.
Unauthorised modifications can lead to serious injuries
or death.
Have a certified specialist workshop perform the repair
work.
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
Check the on-site fusing.
Smoke and/or sparks are emitted during first use:
•
This is not a fault. These phenomena disappear after a
brief runtime.
Noise emission during ignition or cooling:
•
This is not a fault. The metal parts of the device expand
when heated and generate noise.
Sparks and/or flame may be issued from the device during
ignition:
•
This is not a fault. Air might have accumulated in the lines.
Keep a safety distance to the device!
The flame in the combustion chamber does not ignite:
•
Check the filling level of the tank. Refill fuel if the tank is
empty (see chapter Maintenance).
•
Check the fuel filter in the fuel pump for dirt. If it is dirty,
please contact the customer service.
•
Check the fuel for contaminations, e.g. dirt or water. If
required, drain the fuel completely and fill in new fuel (see
chapter Maintenance).
•
Safety shutdown: if the flame dies during operation, the
electronics and the oil pump will be switched off.
Investigate the cause on the basis of the following criteria:
–
For qualified personnel only!
Check the ignition: The distance between the two
ignition electrodes should be 4 to 5 mm.