sound level measuring device controlled via smartphone BS30WP

Individual value measurement

Proceed as follows to select the individual value measurement
as measuring mode:

1. Press the 

Menu

 button (11) to open the context menu for

sensors.

2. Press the 

X/T measurement

 button (13) to switch from

continuous measurement to individual value measurement.

ð

Individual value measurement has been selected as
measuring mode.

ð

Return to the screen displaying the measured values.

ð

The first measured value is automatically determined
and displayed.

SENSORS

MEASUREMENTS

REPORTS

CUSTOMERS

SETTINGS

18

19

17

Refresh measured value

BS30WP

64,9 dbA

Sound level

[45,3 | 64,9]    Ø 56,8

64,9 dbA

No. Designation

Meaning

17

Individual value
indication

Indicates the current sound level.

18 Numeric display

Indicates the minimum, maximum and
average values for the sound level as
well as the current value.

19

Refresh measured
value

 button

Performs an individual value
measurement and refreshes the
displays (17) and (18).

Refreshing the measured value

Proceed as follows to refresh the measured values in the
individual value measurement mode:

1. Press the 

Refresh measured value

 button (19) on the

terminal device.

ð

The appSensor determines the current measured value
which is then displayed on the terminal device.

2. You can also press the 

On / off / measurement

 button (3)

on the appSensor.

ð

The appSensor determines the current measured value
which is then displayed on the terminal device.

Recording measured values

Proceed as follows to record measured values for later
evaluation:

1. Press the 

Menu

 button (11) or the free area below the

measured value display.

ð

The context menu for sensors opens.

2. Press the 

Start recording

 button (16).

ð

The 

REC

 button (20) replaces the 

Menu

 button (11).

3. If you perform a continuous measurement, the measured

values determined from then on will be recorded.

4. If you perform individual value measurements, repeatedly

press the 

On / off / measurement

 button (3) on the

appSensor or the 

Refresh measured value

 button (19) on

the terminal device until you have logged all the required
measured values.

SENSORS

MEASUREMENTS REPORTS

CUSTOMERS

SETTINGS

Reset min / max / Ø

X/T measurement

Disconnect sensor

Sensor settings

Stop recording

20

21

BS30WP

Sound level

[45,3 | 64,9]    Ø 56,8

64,9 dbA

No. Designation

Meaning

20

REC

 button

Opens the sensor settings menu.

21

Stop recording

button

Stops the current recording of
measured values.
Opens the submenu for saving
recordings.

Stopping a recording

Proceed as follows to stop recording the measured values:

1. Press the 

REC

 button (20).

ð

The context menu for sensors opens.

2. Press the 

Stop recording

 button (21).

ð

The context menu for saving the recording opens.

3. You can optionally save, discard or resume the

measurement.

Содержание BS30WP

Страница 1: ...TRT BA BS30WP TC220325TTRT07 004 EN BS30WP EN OPERATING MANUAL SOUND LEVEL MEASURING DEVICE CONTROLLED VIA SMARTPHONE...

Страница 2: ...store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electri...

Страница 3: ...stems such as alarm systems and automatic doors Radio waves may interfere with the operation of such equipment and cause malfunctions Make sure that no other devices are malfunctioning during the use...

Страница 4: ...ment results can be displayed and saved on the terminal device either numerically or in form of a chart Then the measurement data can be sent in PDF or Excel format The app also includes a report gene...

Страница 5: ...ce ensure dry conditions and and protect the device from external influences e g by using a suitable bag Storage When the device is not being used observe the following storage conditions dry and prot...

Страница 6: ...nction on your terminal device is activated 1 Start the Trotec MultiMeasure Mobile app on the terminal device 2 Briefly actuate the On off measurement button 3 three times to switch on the appSensor T...

Страница 7: ...0 Numeric display Indicates the minimum maximum and average values for the sound level as well as the current value 11 Menu button Opens the menu to adjust the settings of the current measurement Info...

Страница 8: ...he terminal device 2 You can also press the On off measurement button 3 on the appSensor The appSensor determines the current measured value which is then displayed on the terminal device Recording me...

Страница 9: ...alues Discards the recorded measured values 24 Continue button Resumes the recording of the measured values without saving Analysing measurements Proceed as follows to call up the saved measurements 1...

Страница 10: ...ot be added to the already saved measurement to be sure but if you save the measurement again with a different name these parameters will be added to the initial measurement Generating a report The re...

Страница 11: ...tails An input mask opens in which you can view and edit all the information for the selected customer as well as directly start a new measurement The New customer button 39 changes In this menu it ca...

Страница 12: ...k the battery voltage and insert new or freshly charged batteries if required Does the distance between appSensor and terminal device exceed the appSensor s radio range see chapter Technical data or a...

Страница 13: ...sionally in accordance with Directive 2006 66 EC of the European Parliament and of the Council of 6 September 2006 on batteries and accumulators Please dispose of batteries and accumulators according...

Страница 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: