Operating manual – air cleaner AirgoClean 10 E

1. Open the device cover (2) by rotating it counter-clockwise.

Note the mark (6) on the right-hand side of the device
cover. You have to rotate the device cover (2) from the
closed (7) to the open position (8).

2

6

8

7

2. Remove the device cover (2) from the device.

2

3. Pull the strip (9) to take the used HEPA filter (10) out of the

device.

10

9

4. Dispose of the used HEPA filter according to the national

regulations.

5. Take the new HEPA filter out of the plastic cover. The front

of the HEPA filter is fitted with a pre-filter made of synthetic
fibre and with the strip (9).

9

Содержание AIRGOCLEAN 10 E

Страница 1: ...TRT BA AIRGOCLEAN10E TC 001 EN AIRGOCLEAN 10 E EN OPERATING MANUAL AIR CLEANER...

Страница 2: ...of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all...

Страница 3: ...place any objects e g clothing on the device Do not use the device outdoors Do not use the device in bathrooms and rooms with a high humidity level Do not use the device in rooms where large amounts...

Страница 4: ...e of synthetic fibre that filters out large dust particles before the air flows into the HEPA filter The HEPA filter is effective against house dust pet allergens cigarette smoke smog and particles wh...

Страница 5: ...e packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up The HEPA filter is pre installed Notice Remove the plas...

Страница 6: ...sk of injury Designation Article number HEPA filter filter class H11 7 160 000 510 Errors and faults The device has been checked for proper functioning several times during production If malfunctions...

Страница 7: ...gressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Visual inspection of the inside of the device for dirt 1 Remove the air filter 2 Use a...

Страница 8: ...er 2 from the closed 7 to the open position 8 2 6 8 7 2 Remove the device cover 2 from the device 2 3 Pull the strip 9 to take the used HEPA filter 10 out of the device 10 9 4 Dispose of the used HEPA...

Страница 9: ...sure level 1 m distance 54 4 dB A Dimensions depth x width x height 183 x 272 x 296 mm Minimum distance to walls and other objects A top B rear C side D front 30 cm 30 cm 30 cm 30 cm Weight 2 5 kg Dis...

Страница 10: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: