background image

5

EN

Operating manual – air cleaner AirgoClean 10 E

Operation

Notice

Avoid open doors and windows.

After being switched on, the device operates fully automatically.

Operating elements

1

No.

Designation

1

On/off switch

Switching the device on / selecting the fan speed

Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
1. Set the on/off switch (1) to the desired fan stage.

Stage I = low fan speed
Stage II = medium fan speed
Stage III = high fan speed

ð

The device is switched on.

Ionization

With this function, the room air is not only cleaned by means of
the HEPA filter, but additionally by means of ions. The released
ions remove pollen, dust, viruses and bacteria from the room
air.
Ionization starts automatically once you switch on the device.
Ionization cannot be switched off.

Shutdown

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Set the on/off switch (1) to 

0

.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Clean the device according to the Maintenance chapter.

Store the device according to the Storage chapter.

Available accessories

Warning

Only use accessories and additional equipment
specified in the operating manual.
Using insertion tools or accessories other than those
specified in the operating manual may cause a risk of
injury.

Designation

Article number

HEPA filter, filter class H11

7.160.000.510

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damages.

Check the on-site fusing.

Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.

The device is loud or vibrates:

Check whether the device is set up in a stable and upright
position.

The device works with reduced capacity:

Check the HEPA filter for dirt. If necessary, clean or replace
the HEPA filter.

The air outlet is obstructed. Make sure that the air outlet is
not blocked. Remove any loose objects from the air outlet.

The HEPA filter's plastic cover was not removed before
installation. Take the HEPA filter out of the plastic cover.

The device works with no capacity or the air quality does
not improve:

Check whether any windows and/or doors of the room are
open. If so, close them.

The HEPA filter is not installed. Install the HEPA filter.

Check the minimum distance to walls or other objects.
Position the device a little more in the room's centre if
required.

The device gives off an unpleasant odour:

Check the HEPA filter for dirt. If necessary, clean or replace
the HEPA filter.

Smoke, e.g. dense tobacco smoke, may produce odours
and contaminations in the air. Ventilate the room.

Содержание AIRGOCLEAN 10 E

Страница 1: ...TRT BA AIRGOCLEAN10E TC 001 EN AIRGOCLEAN 10 E EN OPERATING MANUAL AIR CLEANER...

Страница 2: ...of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all...

Страница 3: ...place any objects e g clothing on the device Do not use the device outdoors Do not use the device in bathrooms and rooms with a high humidity level Do not use the device in rooms where large amounts...

Страница 4: ...e of synthetic fibre that filters out large dust particles before the air flows into the HEPA filter The HEPA filter is effective against house dust pet allergens cigarette smoke smog and particles wh...

Страница 5: ...e packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up The HEPA filter is pre installed Notice Remove the plas...

Страница 6: ...sk of injury Designation Article number HEPA filter filter class H11 7 160 000 510 Errors and faults The device has been checked for proper functioning several times during production If malfunctions...

Страница 7: ...gressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Visual inspection of the inside of the device for dirt 1 Remove the air filter 2 Use a...

Страница 8: ...er 2 from the closed 7 to the open position 8 2 6 8 7 2 Remove the device cover 2 from the device 2 3 Pull the strip 9 to take the used HEPA filter 10 out of the device 10 9 4 Dispose of the used HEPA...

Страница 9: ...sure level 1 m distance 54 4 dB A Dimensions depth x width x height 183 x 272 x 296 mm Minimum distance to walls and other objects A top B rear C side D front 30 cm 30 cm 30 cm 30 cm Weight 2 5 kg Dis...

Страница 10: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: