Trotec 4610000005 Скачать руководство пользователя страница 7

EN

7

submerged clear water pump, near-ground suction TWP 4005 E / TWP 7505 E / TWP 9005 E

Transport and storage

Note

If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.

Transport

Before

 transporting the device, observe the following:

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Do not use the power cable to drag the device.

Only carry the device by the transport handle.

Do not carry the device by holding it at the power cable or
hose.

Storage

When the device is not being used, observe the following
storage conditions:

Dry and protected from frost and heat

In an upright position where it is protected from dust and
direct sunlight

With a cover to protect it from invasive dust, if necessary

Place no further devices or objects on top of the device to
prevent it from being damaged.

If you do not use the device for an extended period of time, it
must be cleaned thoroughly after its last application and before
recommissioning. Deposits and residues could lead to start-up
difficulties.
For restart, please proceed according to the Start-up chapter.

Assembly and installation

Scope of delivery

1 x Submerged clear water pump

1 x Reducer for inner diameters 25 mm and 32 mm as well
as for 1'' internal threads

1 x Backflow preventer with seal (preassembled)

1 x Retainer for backflow preventer

1 x Seal ring

1 x Elbow

1 x Nylon cord (12 m)

1 x Manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power

cable is not damaged and that you do not damage it during
unwinding.

Start-up

Connecting the pipe or hose line

The device may be operated using either a hose line or a pipe.
Ex factory, the device is delivered with a 1 ½" internal thread.
Please observe the following information regarding water
discharge:

Please note that making use of the reducer (7) might
decrease the device performance. The reducer (7) should
be shortened to the used diameter so as not to decrease
the device performance unnecessarily.

Please note that the device cannot be moved as flexibly
when using a solid pipe.

Please note that the maximum particle size is to be
reduced in proportion to the hose or pipe diameter.

Please note that the conveying capacity declines with an
increasing length of the water discharge line.

Hose line

Info

If required, you can cut the reducer (7) off at the
desired diameter.
At delivery the reducer (7) is already assembled with
backflow preventer (9) and retainer (10).

1. Screw the elbow (8) onto the connection with 1 ½" internal

thread (6).

2. Screw the retainer (10) including backflow preventer (9)

onto the elbow (8). Make sure that the backflow
preventer (9) is positioned correctly.

3. Put the seal ring (11) onto the retainer (10) including

backflow preventer (9). The profiled side rests on the
retainer (10).

Содержание 4610000005

Страница 1: ...TRT BA TWP4005E TWP7505E TWP9005E TC211020TTRT02 005 EN TWP 4005 E TWP 7505 E TWP 9005 E EN OPERATING MANUAL SUBMERGED CLEAR WATER PUMP NEAR GROUND SUCTION...

Страница 2: ...ow the manual Information marked with this symbol indicates that the operating manual must be observed You can download the current version of the operating manual and the EU declaration of conformity...

Страница 3: ...ns and the device specific requirements Do not use the power cable to drag the device Hold onto the mains plug while pulling the power cable out of the mains socket Protect the power supply cable agai...

Страница 4: ...continuous operation e g as recirculation pump for ponds The device is not suitable for use as a filter pump in swimming pools and the like The device is not suitable as permanent automatic overflow...

Страница 5: ...not in use Not suitable for pumping potable water This symbol indicates that the device is not suitable for pumping potable water Submerge pump at a slight angle This symbol indicates that the pump mu...

Страница 6: ...e switch on off height can be finely adjusted within the specified range by means of a locking device see technical data The water temperature must not exceed 35 C Info The illustrations in this opera...

Страница 7: ...th seal preassembled 1 x Retainer for backflow preventer 1 x Seal ring 1 x Elbow 1 x Nylon cord 12 m 1 x Manual Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remov...

Страница 8: ...the hose 6 Push the hose inner diameter 25 mm or 32 mm onto the reducer 7 all the way to the stop 7 Affix the hose by means of the hose clamp 8 When using a hose with internal thread 1 Screw the hose...

Страница 9: ...sition by pushing the cable into the float switch locking device 3 at the side of the pump 4 3 Installing the device Please observe the following information regarding the device set up and before swi...

Страница 10: ...d above the adjusted or the maximum switch on height The device will be switched off as soon as the float switch reaches the set or the minimum switch off height Info The device comes equipped with a...

Страница 11: ...ice has been checked for proper functioning several times during production If malfunctions occur nonetheless check the device according to the following list The device does not start Check the power...

Страница 12: ...e delivery head paired with a small hose diameter can cause a reduction of the conveying capacity Check whether the hose line is kinked or blocked Remove kinks and or blockages Note Wait for at least...

Страница 13: ...240 V 50 Hz 230 V 240 V 50 Hz Power consumption 400 W 750 W 900 W Protection type IPX8 IPX8 IPX8 Minimum operating depth 80 mm 80 mm 80 mm Max water level after suction 3 mm 3 mm 3 mm Connection type...