5

submerged clear water pump, near-ground suction TWP 4005 E / TWP 7505 E / TWP 9005 E

Safety signs and labels on the device

Note

Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.

The following safety signs and labels are attached to the device:

Warning of electrical voltage

Information marked with this symbol indicates dangers
to the life and health of persons due to electrical
voltage.

General warning sign

This symbol indicates that you must be aware of the
dangers that can occur when working with the device.

Device may start up without warning

This symbol indicates that the device may start up
without warning when it is switched on.

Do not use damaged power cables or mains plugs

This symbol indicates that the device must no longer be
operated if the power cable is damaged.

Staying in water prohibited

This symbol indicates that the device must not be
operated with persons or animals in the water.

Do not use at freezing temperatures

This symbol indicates that the device must be protected
from frost.

Keep out of the reach of children – not a toy

This symbol indicates that the device is not a toy and is
thus not suitable for children.

Do not pull the mains plug by the power cable

This symbol indicates that you must not pull the mains
plug out of the socket by the power cable.

Pull the mains plug

This symbol indicates that the mains plug must be
removed from the socket when the device is not in use.

Not suitable for pumping potable water

This symbol indicates that the device is not suitable for
pumping potable water.

Submerge pump at a slight angle

This symbol indicates that the pump must be
submerged into the water at a slight angle to allow the
remaining air to escape.

Residual risks

Warning of electrical voltage

Work on the electrical components must only be
carried out by an authorised specialist company!

Warning of electrical voltage

Before any work on the device, remove the mains plug
from the mains socket!
Do not touch the mains plug with wet or damp hands.
Hold onto the mains plug while pulling the power cable
out of the mains socket.

Warning

Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!

Warning

The device is not a toy and does not belong in the
hands of children.

Warning

Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.

Note

If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.

Behaviour in the event of an emergency

1. In an emergency, disconnect the device from the mains

feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.

2. Do not reconnect a defective device to the mains.

Overheating protection

The device is provided with a thermal protection circuit which is
activated by overheating of the device and then switches the
device off.
Switch the device off and let it cool down. Investigate the cause
of overheating. Should the problem persist, please contact the
customer service.

Содержание 4610000005

Страница 1: ...TRT BA TWP4005E TWP7505E TWP9005E TC211020TTRT02 005 EN TWP 4005 E TWP 7505 E TWP 9005 E EN OPERATING MANUAL SUBMERGED CLEAR WATER PUMP NEAR GROUND SUCTION...

Страница 2: ...ow the manual Information marked with this symbol indicates that the operating manual must be observed You can download the current version of the operating manual and the EU declaration of conformity...

Страница 3: ...ns and the device specific requirements Do not use the power cable to drag the device Hold onto the mains plug while pulling the power cable out of the mains socket Protect the power supply cable agai...

Страница 4: ...continuous operation e g as recirculation pump for ponds The device is not suitable for use as a filter pump in swimming pools and the like The device is not suitable as permanent automatic overflow...

Страница 5: ...not in use Not suitable for pumping potable water This symbol indicates that the device is not suitable for pumping potable water Submerge pump at a slight angle This symbol indicates that the pump mu...

Страница 6: ...e switch on off height can be finely adjusted within the specified range by means of a locking device see technical data The water temperature must not exceed 35 C Info The illustrations in this opera...

Страница 7: ...th seal preassembled 1 x Retainer for backflow preventer 1 x Seal ring 1 x Elbow 1 x Nylon cord 12 m 1 x Manual Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remov...

Страница 8: ...the hose 6 Push the hose inner diameter 25 mm or 32 mm onto the reducer 7 all the way to the stop 7 Affix the hose by means of the hose clamp 8 When using a hose with internal thread 1 Screw the hose...

Страница 9: ...sition by pushing the cable into the float switch locking device 3 at the side of the pump 4 3 Installing the device Please observe the following information regarding the device set up and before swi...

Страница 10: ...d above the adjusted or the maximum switch on height The device will be switched off as soon as the float switch reaches the set or the minimum switch off height Info The device comes equipped with a...

Страница 11: ...ice has been checked for proper functioning several times during production If malfunctions occur nonetheless check the device according to the following list The device does not start Check the power...

Страница 12: ...e delivery head paired with a small hose diameter can cause a reduction of the conveying capacity Check whether the hose line is kinked or blocked Remove kinks and or blockages Note Wait for at least...

Страница 13: ...240 V 50 Hz 230 V 240 V 50 Hz Power consumption 400 W 750 W 900 W Protection type IPX8 IPX8 IPX8 Minimum operating depth 80 mm 80 mm 80 mm Max water level after suction 3 mm 3 mm 3 mm Connection type...

Страница 14: ...C 18 cm max 7 5 m max 7 m 42 cm TWP 7505 E max 35 C 18 cm max 10 m max 7 m 60 cm TWP 9005 E max 35 C 18 cm max 11 5 m max 7 m 60 cm Performance chart delivery head flow rate TWP 4005 E 9 000 6 000 3...