Trotec 4610000005 Скачать руководство пользователя страница 2

2

EN

submerged clear water pump, near-ground suction TWP 4005 E / TWP 7505 E / TWP 9005 E

Table of contents

Notes regarding the operating manual................................. 2

Safety ..................................................................................... 2

Information about the device................................................ 6

Transport and storage........................................................... 7

Assembly and installation..................................................... 7

Operation ............................................................................. 10

Errors and faults.................................................................. 11

Maintenance ........................................................................ 12

Technical annex................................................................... 13

Disposal ............................................................................... 15

Notes regarding the operating manual

Symbols

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Note

This signal word indicates important information (e.g.
material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
operating manual must be observed.

You can download the current version of the operating manual
and the EU declaration of conformity via the following link:

TWP 4005 E

http://hub.trotec.com/?id=40406

TWP 7505 E

https://hub.trotec.com/?id=42885

TWP 9005 E

https://hub.trotec.com/?id=42886

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.

Save all warnings and instructions for future
reference.

This appliance can be used by children aged 
from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given
supervision or instruction concerning use of the
appliance in a safe way and understand the hazards
involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.

Содержание 4610000005

Страница 1: ...TRT BA TWP4005E TWP7505E TWP9005E TC211020TTRT02 005 EN TWP 4005 E TWP 7505 E TWP 9005 E EN OPERATING MANUAL SUBMERGED CLEAR WATER PUMP NEAR GROUND SUCTION...

Страница 2: ...ow the manual Information marked with this symbol indicates that the operating manual must be observed You can download the current version of the operating manual and the EU declaration of conformity...

Страница 3: ...ns and the device specific requirements Do not use the power cable to drag the device Hold onto the mains plug while pulling the power cable out of the mains socket Protect the power supply cable agai...

Страница 4: ...continuous operation e g as recirculation pump for ponds The device is not suitable for use as a filter pump in swimming pools and the like The device is not suitable as permanent automatic overflow...

Страница 5: ...not in use Not suitable for pumping potable water This symbol indicates that the device is not suitable for pumping potable water Submerge pump at a slight angle This symbol indicates that the pump mu...

Страница 6: ...e switch on off height can be finely adjusted within the specified range by means of a locking device see technical data The water temperature must not exceed 35 C Info The illustrations in this opera...

Страница 7: ...th seal preassembled 1 x Retainer for backflow preventer 1 x Seal ring 1 x Elbow 1 x Nylon cord 12 m 1 x Manual Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remov...

Страница 8: ...the hose 6 Push the hose inner diameter 25 mm or 32 mm onto the reducer 7 all the way to the stop 7 Affix the hose by means of the hose clamp 8 When using a hose with internal thread 1 Screw the hose...

Страница 9: ...sition by pushing the cable into the float switch locking device 3 at the side of the pump 4 3 Installing the device Please observe the following information regarding the device set up and before swi...

Страница 10: ...d above the adjusted or the maximum switch on height The device will be switched off as soon as the float switch reaches the set or the minimum switch off height Info The device comes equipped with a...

Страница 11: ...ice has been checked for proper functioning several times during production If malfunctions occur nonetheless check the device according to the following list The device does not start Check the power...

Страница 12: ...e delivery head paired with a small hose diameter can cause a reduction of the conveying capacity Check whether the hose line is kinked or blocked Remove kinks and or blockages Note Wait for at least...

Страница 13: ...240 V 50 Hz 230 V 240 V 50 Hz Power consumption 400 W 750 W 900 W Protection type IPX8 IPX8 IPX8 Minimum operating depth 80 mm 80 mm 80 mm Max water level after suction 3 mm 3 mm 3 mm Connection type...

Страница 14: ...C 18 cm max 7 5 m max 7 m 42 cm TWP 7505 E max 35 C 18 cm max 10 m max 7 m 60 cm TWP 9005 E max 35 C 18 cm max 11 5 m max 7 m 60 cm Performance chart delivery head flow rate TWP 4005 E 9 000 6 000 3...

Страница 15: ...ained from your municipality or local administration You can also find out about other return options that apply for many EU countries on the website https hub trotec com id 45090 Otherwise please con...

Страница 16: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: