Assembling the upper part of the housing
1. Attach the protective grid.
2. Place the upper part of the housing on the device.
3. Tighten the 6 screws at the upper part of the housing.
Adjusting the air pressure for the pump
Ideally, the air pressure should range between 0.32 bar
and 0.36 bar. During operation, the air pressure can be read
from the pressure gauge (16).
Info
If the air pressure exceeds 0.36 bar, a flame emerges
from the air outlet of the device. The device then stops
running.
If the pressure is lower than 0.32 bar, the device
continues to operate, but with a reduced performance.
1. Adjust the air pressure during operation by means of a
slotted screwdriver. For lowering turn the screw
counter-clockwise; for increasing carefully turn it
clockwise.