Installation Guide Qiwi Switches
Document no. 120-10X.44 11/2016 ENG
Seite 9 von 16
4.
First start-up
4.1.
Default settings
Order no. 006-120-100
The device with the Order no. 006-120-100 is an unmanaged Switch, therefore no configuration can
be made. After wiring the power supply connection the Switch transfers data on all Ethernet ports.
Order no. 006-120-101
The device is delivered pre-configured. The factory configuration is chosen so that after switching on
the device sends the data immediately to all Ethernet ports. The following settings are set at the
factory:
► Web interface IP address:
192.168.0.2
► Web interface user name:
admin
► Web interface password:
password
► Web interface access:
Ethernet port 1-6
4.2.
Configuration
Order no. 006-120-101
Proceed as follows for the first commissioning:
1. Connect the power supply.
2. Connect the PC / notebook to one of the Ethernet ports 1-6 of the device.
3. The connected PC / laptop must have the following network settings:
► IP address:
192.168.0.1
► Subnet mask:
255.255.255.0
4. Start the web browser and enter the LAN-IP address of the device.
5. Perform the desired configuration of the device.
6. Connect the Switch with your network devices.