Installation Guide Qiwi Switches
Document no. 120-10X.44 11/2016 ENG
Seite 12 von 16
Digital Input
Parameter
min.
typ.
max.
Dimension
Low level (logic 0)
-0.3
0
5
VDC
High level (logic 1)
11
24
30
VDC
Isolation
Parameter
min.
typ.
max.
Dimension
Data ports
↔ data ports
± 2250
-
-
VDC
Data ports
↔ V1, V2, USB, fault contact
± 2250
-
-
VDC
Data ports
↔ housing (grounding)
± 2250
-
-
VDC
Fault contact
↔ V1, V2, USB, housing
± 1500
-
-
VDC
Housing (grounding)
↔ V1, V2, USB
± 850
-
-
VDC
6.2.
Mechanical
Parameter
typ.
Dimension
Dimensions (H x B x T, ± 0,5 mm)
64 x 105 x 48
mm
Mass net
250
g
Housing protection class
IP20
-
Mounting
DIN rail
-
6.3.
Environment
Parameter
min.
typ.
max.
Dimension
Ambient temperature during operation
-40
-
+70
°C
Ambient temperature storage
-40
-
+85
°C
Humidity (not condensing)
10
-
95
%
Air pressure during operation
795
(+2000m)
-
-
hPa