Triton T40i Скачать руководство пользователя страница 8

6

T40i

FITTING TO THE WALL

•  Unscrew the top and bottom retaining screws 

(fig.6)

 and lift the cover from the backplate.

NOTE: 

The control knob is an integral part of 

the cover. DO NOT attempt to remove it.

•  Decide on the cable entry position, either top 

or rear.

•  If top entry position is chosen, the cut-out in 

the backplate must be removed 

(fig.7)

.

•  Loosely connect the supplied flexible hose to 

the T40i inlet connection and the mixer valve 
outlet. Using the backplate as a template, 
hold it against the wall, making sure there is 
some slack in the hose and mark the position 
of the fixing holes 

(fig.8)

. Remove the 

flexible hose from the T40i and mixer valve.

Fig.8

Fig.7

Fig.6

WARNING

Check there are no hidden cables or  

pipes before drilling holes for wall plugs.

Use great care when using power tools

near water. The use of a residual current 

device (RCD) is recommended when  

using power tools.

•  Drill and plug the wall. An appropriate drill bit 

should be used. If the wall is brick, 
plasterboard or a soft building block, 
appropriate wall plugs and screws should be 
fitted.

•  Screw the top fixing screw into position 

leaving the base of the screw head protruding 
6mm out from the wall.

•  Hook the backplate over the top screw and fit 

the bottom fixing screw into position.

•  The bottom fixing hole is elongated to allow 

for out of square adjustment. Tighten both 
screws when correctly positioned.

Содержание T40i

Страница 1: ...recommended for all electrical appliances The hose supplied with this product is an integral part of the safety system Use a genuine Triton handset with this product Failure to use genuine Triton acce...

Страница 2: ...al and multiple installations please contact Triton s specification advisory service before installation Telephone E mail 024 7637 2222 technical tritonshowers co uk WARNING This appliance can be used...

Страница 3: ...when making connections to the flexible hose or sprayhead finger tightness is sufficient 1 12 All hose connections MUST be completed BEFORE making the electrical connections 2 ELECTRICAL 2 1 The insta...

Страница 4: ...r supply NOTE It must NOT be used with instantaneous water heaters This product is suitable for installation in a bathroom DO NOT install the unit so close to the bath that the supplied hose becomes t...

Страница 5: ...crew fixings 3 Terminal block 4 Outlet connection 5 Wall screw fixings 6 Rear cable entry 7 Switch assembly 8 Motor 9 Pump assembly 10 Inlet pipe 11 Outlet pipe 12 Inlet connection MAIN COMPONENTS Fig...

Страница 6: ...it will NOT be in direct contact with water from the sprayhead Both hot and cold water supplies to the existing bath tap mixer valve MUST be direct and separate from any other outlets or connections D...

Страница 7: ...early identifiable but out of reach of a person using a fixed bath or shower except for the cord of a cord operated switch The installation and wiring MUST comply with the current IEE regulations The...

Страница 8: ...ig 8 Remove the flexible hose from the T40i and mixer valve Fig 8 Fig 7 Fig 6 WARNING Check there are no hidden cables or pipes before drilling holes for wall plugs Use great care when using power too...

Страница 9: ...system and to check for leaks Turn off the water Replace the sprayhead and turn the water on again Leave running to waste until a smooth even if poor flow of water is obtained Turn off the water Fitt...

Страница 10: ...r Route the cable into the unit and connect to the terminal block fig 11 as follows Earth cable to terminal marked E Neutral cable to terminal marked N Live cable to terminal marked L IMPORTANT Fully...

Страница 11: ...n with the two retaining screws 6 Turn on the water supply at the mixer valve tap and adjust to a normal showering temperature 7 Make sure the control knob is at the stop position Switch on the electr...

Страница 12: ...soapy water DO NOT use abrasive or aggressive chemical cleaning products as this may affect the product surface finish and invalidate your guarantee MAINTENANCE Before cleaning turn off the unit at t...

Страница 13: ...Ref Description Part No 1 Microswitch 22012460 2 Switch assembly 82500130 3 Outlet pipe assembly 7052027 4 Inlet pipe assembly 7052443 Cover assembly 80400020 Flexible hose chrome 28100240 SPARE PARTS...

Страница 14: ...2 1 1 Stop pump motor by switching to stop Check the cold water cistern is full Ensure water pipes are not blocked Check there is no simultaneous demand from the cistern while showering 2 2 Air lock i...

Страница 15: ...ic Producers take back scheme PTS registration number WEE EJ3466QV Valpak Distributor take back scheme DTS registration number 9659 All our electric products are labelled accordingly with the crossed...

Страница 16: ...credit debit card excluding American Express or Diners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given dur...

Отзывы: