Triton T40i Скачать руководство пользователя страница 3

1

T40i 

IMPORTANT - GENERAL GUIDANCE NOTES

GENERAL

1.1

  Products manufactured by Triton are safe 

and without risk provided they are 
installed, used and maintained in good 
working order in accordance with our 
instructions and recommendations.

1.2

 

DO NOT

 operate the unit if it is frozen or 

suspected of being frozen. It must thaw 
out before using.

1.3

  Switch off the electrical supply at the 

mains before removing the cover.

1.4

  Read all of these instructions and retain 

them for later use.

1.5

 

DO NOT

 connect to the mains water 

supply.

1.6

  Isolate electrical and water supplies 

BEFORE

 proceeding with the installation.

1.7

 

DO NOT

 connect to modulating type 

combination boilers, multi-point hot water 
heaters and unvented or thermal storage 
systems.

1.8

  Contact Customer Service (see back 

page), if any of the following occur: 

a) If water ceases to flow during use. 
b) If the unit shows a distinct change in 
performance. 
c) If the pump is frozen. 
d) If water has entered inside the unit 
because of incorrectly fitted cover.

1.9

 

DO NOT

 restrict flow out of the pump by 

placing the sprayhead in direct contact 
with your body.

1.10

 

This product is not suitable for 
mounting into steam rooms or 
steam cubicles.

1.11

 

DO NOT

 use excessive force when making 

connections to the flexible hose or 
sprayhead, finger tightness is sufficient.

1.12

  All hose connections 

MUST

 be completed 

BEFORE

 making the electrical 

connections.

ELECTRICAL

2.1

  The installation must comply with BS 7671 

‘Requirements for electrical installations’ 
(IEE wiring regulations) or any particular 
regulations as specified by the  local 
Electrical Supply Company.

2.2

 

This appliance MUST be earthed.

2.3

  In accordance with ‘The Plugs and Sockets 

etc. (Safety) Regulations 1994’, this 
appliance is intended to be permanently 
connected to the fixed wiring of the 
electrical mains system.

2.4

  Make sure all electrical connections are 

tight to prevent overheating.

2.5

  Fuses do not give personal protection 

against electric shock.

2.6

  A 30mA residual current device (RCD) 

MUST

 be installed in all UK electric and 

pumped shower circuits. This may be part 
of the consumer unit or a separate unit.

2.7

  Switch off immediately at isolating switch 

if water ceases to flow during use.

2.8

 

Switch off at isolating switch when 
not in use. This is a safety procedure 
recommended with all electrical 
appliances.

2.9

  Other electrical equipment i.e. extractor 

fans, pumps, 

MUST NOT

 be connected to 

the circuits within the unit.

3.0 

As with all electrical appliances it is 
recommended to have the unit and 
installation checked at least every two 
years by a competent electrician to ensure 
there is no deterioration due to age and 
usage.

Содержание T40i

Страница 1: ...recommended for all electrical appliances The hose supplied with this product is an integral part of the safety system Use a genuine Triton handset with this product Failure to use genuine Triton acce...

Страница 2: ...al and multiple installations please contact Triton s specification advisory service before installation Telephone E mail 024 7637 2222 technical tritonshowers co uk WARNING This appliance can be used...

Страница 3: ...when making connections to the flexible hose or sprayhead finger tightness is sufficient 1 12 All hose connections MUST be completed BEFORE making the electrical connections 2 ELECTRICAL 2 1 The insta...

Страница 4: ...r supply NOTE It must NOT be used with instantaneous water heaters This product is suitable for installation in a bathroom DO NOT install the unit so close to the bath that the supplied hose becomes t...

Страница 5: ...crew fixings 3 Terminal block 4 Outlet connection 5 Wall screw fixings 6 Rear cable entry 7 Switch assembly 8 Motor 9 Pump assembly 10 Inlet pipe 11 Outlet pipe 12 Inlet connection MAIN COMPONENTS Fig...

Страница 6: ...it will NOT be in direct contact with water from the sprayhead Both hot and cold water supplies to the existing bath tap mixer valve MUST be direct and separate from any other outlets or connections D...

Страница 7: ...early identifiable but out of reach of a person using a fixed bath or shower except for the cord of a cord operated switch The installation and wiring MUST comply with the current IEE regulations The...

Страница 8: ...ig 8 Remove the flexible hose from the T40i and mixer valve Fig 8 Fig 7 Fig 6 WARNING Check there are no hidden cables or pipes before drilling holes for wall plugs Use great care when using power too...

Страница 9: ...system and to check for leaks Turn off the water Replace the sprayhead and turn the water on again Leave running to waste until a smooth even if poor flow of water is obtained Turn off the water Fitt...

Страница 10: ...r Route the cable into the unit and connect to the terminal block fig 11 as follows Earth cable to terminal marked E Neutral cable to terminal marked N Live cable to terminal marked L IMPORTANT Fully...

Страница 11: ...n with the two retaining screws 6 Turn on the water supply at the mixer valve tap and adjust to a normal showering temperature 7 Make sure the control knob is at the stop position Switch on the electr...

Страница 12: ...soapy water DO NOT use abrasive or aggressive chemical cleaning products as this may affect the product surface finish and invalidate your guarantee MAINTENANCE Before cleaning turn off the unit at t...

Страница 13: ...Ref Description Part No 1 Microswitch 22012460 2 Switch assembly 82500130 3 Outlet pipe assembly 7052027 4 Inlet pipe assembly 7052443 Cover assembly 80400020 Flexible hose chrome 28100240 SPARE PARTS...

Страница 14: ...2 1 1 Stop pump motor by switching to stop Check the cold water cistern is full Ensure water pipes are not blocked Check there is no simultaneous demand from the cistern while showering 2 2 Air lock i...

Страница 15: ...ic Producers take back scheme PTS registration number WEE EJ3466QV Valpak Distributor take back scheme DTS registration number 9659 All our electric products are labelled accordingly with the crossed...

Страница 16: ...credit debit card excluding American Express or Diners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given dur...