Triton T40i Скачать руководство пользователя страница 4

2

T40i

INTRODUCTION

This book contains all the necessary fitting and 
operating instructions for your T40i booster 
pump. Please read them carefully. 
The installation must be carried out by a suitably 
qualified person and in the sequence of this 
instruction book.
Care taken during the installation will ensure a 
long, trouble-free life from your booster pump.
The T40i booster pump is designed to improve 
the flow rate through an existing bath/tap mixer 
valve. It is 

NOT

 designed to pressurise the water 

supply but only to assist the flow.

IT MUST ONLY

 be fitted to new or existing 

gravity fed shower mixer systems.
The unit is easy to install requiring no plumbing, 
only simple screw-on hose connections and a 
suitable power supply.

NOTE:

 

It must NOT be used with 

instantaneous water heaters.

This product is suitable for installation in a 
bathroom.

DO NOT

 install the unit so close to the bath that 

the supplied hose becomes twisted or kinked and 
restricts the water flow.

SPECIFICATIONS

Electrical

Voltage: ............................... 240V 
Pump motor rating: ............. 73 Watt (nominal)

Water

Inlet connection – ½” BSP male thread. 
Outlet connection – ½” BSP male thread.

Entry Points

Water – bottom left. 
Cable – top right, rear right.

Materials

Backplate, cover, controls – ABS.

Dimensions (in millimetres)

Height ....... 230 
Width ........ 217 
Depth ........ 80

Standards and Approvals

Splashproof rating - IPX4
Complies with the requirements of current British 
and European safety standards for household and 
similar electrical appliances.
Complies with requirements of the British 
Electrotechnical Approvals Board (BEAB).
Meets with Compliance with European 
Community Directives (CE).

This product is rated at: 

15 minutes on / 45 minutes off.

Содержание T40i

Страница 1: ...recommended for all electrical appliances The hose supplied with this product is an integral part of the safety system Use a genuine Triton handset with this product Failure to use genuine Triton acce...

Страница 2: ...al and multiple installations please contact Triton s specification advisory service before installation Telephone E mail 024 7637 2222 technical tritonshowers co uk WARNING This appliance can be used...

Страница 3: ...when making connections to the flexible hose or sprayhead finger tightness is sufficient 1 12 All hose connections MUST be completed BEFORE making the electrical connections 2 ELECTRICAL 2 1 The insta...

Страница 4: ...r supply NOTE It must NOT be used with instantaneous water heaters This product is suitable for installation in a bathroom DO NOT install the unit so close to the bath that the supplied hose becomes t...

Страница 5: ...crew fixings 3 Terminal block 4 Outlet connection 5 Wall screw fixings 6 Rear cable entry 7 Switch assembly 8 Motor 9 Pump assembly 10 Inlet pipe 11 Outlet pipe 12 Inlet connection MAIN COMPONENTS Fig...

Страница 6: ...it will NOT be in direct contact with water from the sprayhead Both hot and cold water supplies to the existing bath tap mixer valve MUST be direct and separate from any other outlets or connections D...

Страница 7: ...early identifiable but out of reach of a person using a fixed bath or shower except for the cord of a cord operated switch The installation and wiring MUST comply with the current IEE regulations The...

Страница 8: ...ig 8 Remove the flexible hose from the T40i and mixer valve Fig 8 Fig 7 Fig 6 WARNING Check there are no hidden cables or pipes before drilling holes for wall plugs Use great care when using power too...

Страница 9: ...system and to check for leaks Turn off the water Replace the sprayhead and turn the water on again Leave running to waste until a smooth even if poor flow of water is obtained Turn off the water Fitt...

Страница 10: ...r Route the cable into the unit and connect to the terminal block fig 11 as follows Earth cable to terminal marked E Neutral cable to terminal marked N Live cable to terminal marked L IMPORTANT Fully...

Страница 11: ...n with the two retaining screws 6 Turn on the water supply at the mixer valve tap and adjust to a normal showering temperature 7 Make sure the control knob is at the stop position Switch on the electr...

Страница 12: ...soapy water DO NOT use abrasive or aggressive chemical cleaning products as this may affect the product surface finish and invalidate your guarantee MAINTENANCE Before cleaning turn off the unit at t...

Страница 13: ...Ref Description Part No 1 Microswitch 22012460 2 Switch assembly 82500130 3 Outlet pipe assembly 7052027 4 Inlet pipe assembly 7052443 Cover assembly 80400020 Flexible hose chrome 28100240 SPARE PARTS...

Страница 14: ...2 1 1 Stop pump motor by switching to stop Check the cold water cistern is full Ensure water pipes are not blocked Check there is no simultaneous demand from the cistern while showering 2 2 Air lock i...

Страница 15: ...ic Producers take back scheme PTS registration number WEE EJ3466QV Valpak Distributor take back scheme DTS registration number 9659 All our electric products are labelled accordingly with the crossed...

Страница 16: ...credit debit card excluding American Express or Diners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given dur...

Отзывы: