16
Fitting Procedure
• Turn off water supply either at the mains
stopvalve or the isolating stopvalve.
• Temporarily connect the mains water supply
to the inlet of the shower using a 15mm x
15mm compression fitting.
• Use the backplate as a template making sure
it is level and mark the fixing holes
(fig.10)
.
• Remove the unit from the wall. Drill and
plug the wall. An appropriate drill bit should
be used. If the wall is plasterboard or a soft
building block, appropriate wall plugs should
be fitted.
• Screw the top fixing screw into position
leaving the base of the screw head protruding
around 6mm out from the wall. Hook the
backplate over the top screw and fit the
bottom fixing screw into position.
• Connect the mains water supply to the inlet
DO NOT
use excessive force when making
the connection.
• Make sure the backplate is square on the
wall and tighten the retaining screws which
hold it to the wall.
• Turn on the mains water supply and check
for leaks in the pipework connection to the
shower.
NOTE:
At this stage no water can flow through
the unit.
IMPORTANT:
A suitable sealant should always
be used to seal around the incoming pipework to
prevent water entering the wall.
• Route the cable into the shower unit for
connection to the terminal block
(fig.11)
as follows:
Earth
cable to terminal marked
Neutral
cable to terminal marked
N
Live
cable to terminal marked
L
WARNING
Check there are no hidden cables or pipes
before drilling holes for wall plugs. Use great
care when using power tools near water.
The use of a residual current device (RCD) is
recommended when using power tools.
Fig.10
Fixing hole
Fixing hole
Terminal
block
Fig.11
7
Continued
SECTION
SECTION