Electric shower
FAULT FINDING/TROUBLESHOOTING
Problem
Cause
Action
5
Shower varies from
normal temperature to
cold during use.
5.1
Water pressure has
dropped below
minimum required.
5.1.1
Wait until the water pressure resumes to
normal.
6
Pressure relief device has
operated
(water ejected
from PRD tube)
.
6.1
Blocked shower head.
6.1.1
Clean or replace blocked sprayplate in
shower head and then fit new PRD.
6.2
Twisted/blocked
flexible shower hose.
6.2.1
Check for free passage through hose.
Replace the hose if necessary and fit new
PRD.
6.3
Shower head not
removed while
commissioning.
6.3.1
Fit new PRD. Commission unit with shower
head removed.
6.4
Water pressure above
specified maximum for
unit
(see rating label).
6.4.1
Fit pressure reducing valve to inlet and then
fit new PRD.
7
Shower fails to shut off
flow when Start/Stop
button is pressed.
7.1
Faulty Start/Stop
switch.
7.1.1
Replace switch.
7.2
Debris in solenoid
valve.
7.2.1
Replace solenoid valve.
7.3
Unit malfunction.
7.3.1
Have unit checked. Contact Customer
Experience.
FAULT FINDING
Important:
Switch off the electricity at the mains supply and remove the circuit fuse before
attempting any fault finding inside the unit.
Problem/Symptom Cause
Action/Cure
NOTE:
Identify cause of operation before fitting new PRD unit.
When fitting a new PRD, follow the commissioning procedure.
It is advised all electrical maintenance/repairs to the shower
should be carried out by a suitably qualified person.
In the unlikely event of a fault occurring please contact Triton Customer Service.
DO NOT remove the shower from the installation.