background image

Triton Showers 

Triton Road 

Nuneaton 

Warwickshire  CV11 4NR

Triton is a division of Norcros Group (Holdings) Limited

TRITON reserve the right to change product specification without prior notice. E&OA. © TRITON SHOWERS 2008

Service Policy

In the event of a complaint occurring, the following 

procedure should be followed:

1

  Telephone Customer Service on  

0870 067 3333

 

(0845 762 6591 in Scotland and 

in Northern Ireland)

, having available the model 

number and power rating of the product, together 

with the date of purchase.

2

  Triton Customer Service will be able to confirm 

whether the fault can be rectified by either the 

provision of a replacement part or a site visit 

from a qualified Triton service engineer.

 

If a service call is required the unit must be fully 

installed for the call to be booked and the date 

confirmed. In order to speed up your request, 

please have your postcode available when 

booking a service call.

4

  It is essential that you or an appointed  

representative (who must be a person of 18 years 

of age or more) is present during the service 

engineer's visit and receipt of purchase is shown.

5

 

A charge will be made in the event of an aborted 

service call by you but not by us, or where a call 

under the terms of guarantee has been booked 

and the failure is not product related (i.e. scaling 

and furring, incorrect water pressure). 

6

  If the product is no longer covered by the 

guarantee, a charge will be made for the site 

visit and for any parts supplied.

7

  Service charges are based on the account being 

settled when work is complete, the engineer 

will then request payment for the invoice. If this 

is not made to the service engineer or settled 

within ten working days, an administration 

charge will be added.

Replacement Parts Policy

Availability:

 It is the policy of Triton to maintain 

availability of parts for the current range of 

products for supply after the guarantee has 

expired. Stocks of spare parts will be maintained 

for the duration of the product’s manufacture and 

for a period of five years thereafter.

  In the event of a spare part not being available a 

substitute part will be supplied.

Payment: 

The following payment methods can be 

used to obtain spare parts:

1

   By post, pre-payment of pro forma invoice by 

cheque or money order.

2

   By telephone, quoting credit card (MasterCard 

or Visa) details.

3

   By website order, www.tritonshowers.co.uk

TRiTon STandaRd GuaRanTee

Triton guarantee this product against all mechanical 

defects arising from faulty workmanship or materials 

for a period of three years for domestic use only, 

from the date of purchase, provided that it has been 

installed by a competent person in full accordance 

with the fitting instructions.
Any part found to be defective during this 

guarantee period we undertake to repair or replace 

at our option without charge so long as it has been 

properly maintained and operated in accordance 

with the operating instructions, and has not been 

subject to misuse or damage.
This product must not be taken apart, modified or 

repaired except by a person authorised by Triton. 

This guarantee applies only to products installed 

within the United Kingdom and does not apply to 

products used commercially. This guarantee does 

not affect your statutory rights.

What is not covered:

1

 

Breakdown due to: 

a)

 use other than domestic 

use by you or your resident family;  

b)

 wilful act or neglect; 

c)

 any malfunction 

resulting from the incorrect use or quality of 

water or incorrect setting of controls; 

d)

 faulty 

installation.

2

 

Repair costs for damage caused by foreign 

objects or substances.

3

  Total loss of the product due to non-availability 

of parts.

4

  Compensation for loss of use of the product or 

consequential loss of any kind.

5

 

Call out charges where no fault has been found 

with the appliance.

The cost of repair or replacement of 

showerheads, hoses, riser rails and/or wall 

brackets or any other accessories installed at the 

same time.

The cost of routine maintenance, adjustments, 

overhaul modifications or loss or damage arising 

therefrom, including the cost of repairing 

damage, breakdown, malfunction caused by 

corrosion, furring, pipe scaling, limescale, system 

debris or frost.

Customer Service: 

0870 067 3333

Scottish and northern ireland 

Customer Service: 

0845 762 6591

 Trade installer Hotline: 

0870 067 3767 

Fax: 

 

0870 067 3334

www.tritonshowers.co.uk 

e mail: [email protected]

Содержание COMBI 2180206H

Страница 1: ...Installation and operating instructions Combi HP Thermostatic mixer shower T00219 2180206H March 2007 Installers please note these instructions are to be left with the user...

Страница 2: ...or panel 18 Flushing procedure 20 Fitting the tamperproof fixed head Exposed 21 Fitting the tamperproof fixed head Built in 22 Fitting the fixed head Built in 23 Fitting the bulkhead 24 Operating the...

Страница 3: ...um switch on flow rate of 3 litres per minute At flow rates between 3 and 8 litres per minute the appliance must be capable of raising the water temperature to a minimum of 52 C The water temperature...

Страница 4: ...knob 10 Knob trim 11 Max temperature override button 12 Cover 13 Inlet trims 14 Outlet trim 15 Outlet blanking trim 16 Flush mount plate 17 Flush mount cover 18 Trim ring 19 Cartridge fixing screws 20...

Страница 5: ...essures at the mixer valve This should be installed as indicated on the appropriate diagrams shown on the following pages and set to within the specification of the valve For the best performance of t...

Страница 6: ...ual pressures The pump must be capable of maintaining a minimum running pressure of 1 bar c Unvented mains pressure showers fig 4 The shower control can be installed with an unvented stored hot water...

Страница 7: ...d to make sure the unit is not damaged by excess pressures This may already be installed externally or internally within the thermal store check with thermal store manufacturer The layout and sizing o...

Страница 8: ...sitioned where it will be subjected to freezing conditions Refer to fig 6 for correct siting of the shower Position the shower and showerhead on the wall so that all controls can be comfortably reache...

Страница 9: ...Water pressure must not fall below specification of the shower Note The hot water pipe entry must be on the left Rising and falling supplies Having decided on the position of the shower and direction...

Страница 10: ...the inlet trims between the pipes If the pipe separation gap is 153 mm or greater have the long side of the inlet trims between the pipes fig 12 If in any doubt try the cover to see if it fits properl...

Страница 11: ...and fully tighten the compression nut fig 19 Before securing the tamperproof fixed head to the wall connect a hose to the pipework and direct to waste If fitting a riser rail connect the shower hose...

Страница 12: ...for two circular recesses measuring 32 mm diameter by 14 mm depth to accept the rear entry pipe trims fig 23 Flush pipework to clear the system of all debris and check for leaks Important The inlet el...

Страница 13: ...ith an O ring Make sure the adaptor is fitted with the pipe end in the valve housing fig 17 Fit the blanking plug into the top outlet hole using an O ring to seal it fig 18 If fitting a tamperproof fi...

Страница 14: ...g 19 Secure the cover with two screws fig 21 Locate the lugs on the trim ring in the holes on the cover and twist clockwise fig 22 Complete the fitting of your shower accessories T00248 Fig 28 N 004 A...

Страница 15: ...be installed such that the flow is not significantly affected by other taps and appliances being operated elsewhere on the premises Water pressure must not fall below the specification of the valve Th...

Страница 16: ...adaptor needs to be fitted into the top outlet hole in the valve housing fig 16 The adaptor is sealed with an O ring Make sure the adaptor is fitted with the hose end fig 17 in the valve housing Fit...

Страница 17: ...then to Cold if necessary depress the maximum temperature override button Check for leaks and remedy if necessary If a fixed head is installed make good the outlet pipe channel Note If fitting a fixe...

Страница 18: ...and washers provided fig 41 If a fixed head is to be installed the outlet adaptor needs to be fitted into the top outlet hole in the valve housing fig 16 The adaptor is sealed with an O ring Make sure...

Страница 19: ...he fixed head should protrude from the surface of the wall between 50 mm and 65 mm Before fitting the fixed head to the wall connect a hose to the pipework and direct to waste If fitting a riser rail...

Страница 20: ...hower position and whether the hot and cold water supplies will enter the shower from the top falling the bottom rising or the rear Mark the wall for an opening of about 93 mm diameter Cut the opening...

Страница 21: ...ake sure the hole in the panel for the outlet pipe is no larger than required either BSP or 15 mm Should the shroud protrude beyond the wall surface trim flush with a sharp knife fig 34 Place a ring o...

Страница 22: ...refully hooked out using a suitable tool such as an allen key f Push the flushing cartridge into the housing fig 52 Attach a hose to the flushing cartridge outlet and make sure it is directed to waste...

Страница 23: ...plied Secure the pipe to the fixed head unit using the compression nut and olive supplied fig 55 Secure the fixed head to the wall with the three screws supplied fig 56 Screw on the adjustable showerh...

Страница 24: ...make sure fixed head is in the correct attitude Mark the position of the three fixing holes fig 61 Remove the fixed head Drill and plug the holes using the plugs supplied Screw the fixed head assembl...

Страница 25: ...placed on the pipe correctly with the inscription FRONT facing away from the wall This washer holds the pipe in position Slide the bushing over the pipe and push it tight against the wall Slide the O...

Страница 26: ...size if required The threaded connector should protrude from the wall surface between 8 mm and 13 mm Make good the wall Screw the bulkhead elbow to the threaded connector using PTFE tape to seal the t...

Страница 27: ...his automatically stops the water flow As a safety measure the shower has a built in maximum temperature stop to prevent accidentally exceeding the highest desired temperature The stop comes in a fact...

Страница 28: ...and remove the temperature control knob fig 79 Now remove the temperature control disc together with the wavy washer The control disc houses the maximum temperature stop mechanism fig 80 To increase t...

Страница 29: ...Cover shroud white exposed valve 7041444 chrome exposed valve 7041445 gold exposed valve 7041446 10 Trim ring white 7051441 chrome 7051442 gold 7051443 gold flush 7051477 11 Trim sets white 83303680...

Страница 30: ...32 available on request 21 Nutted male thread fitting 7032915 22 Tamperproof fixed head built in 96200250 23 Tamperproof fixed head exposed 96200240 Fixed head assembly white 22450060 Fixing kit 22009...

Страница 31: ...demand make sure a dedicated supply to mixer Make sure service valves are fully open Turn off the shower and consult a competent plumber or contact Triton Customer Service 1 1 1 1 2 1 1 3 1 1 4 1 1 5...

Страница 32: ...ult a suitably competent plumber Renew cartridge internal seals are not serviceable 3 2 1 3 3 1 3 4 1 3 4 2 4 1 1 5 1 1 6 1 1 Shower unit blocked Showerhead blocked Reduced flow rate when other outlet...

Страница 33: ...31 Combi HP thermostatic mixer shower...

Страница 34: ...32 Combi HP thermostatic mixer shower...

Страница 35: ...33 Combi HP thermostatic mixer shower...

Страница 36: ...a substitute part will be supplied Payment The following payment methods can be used to obtain spare parts 1 By post pre payment of pro forma invoice by cheque or money order 2 By telephone quoting c...

Отзывы: