FAULT FINDING
Problem/Symptom Cause
Action/Cure
X-006-A
Turn the control knob anti-clockwise.
Turn the control anti-clockwise.
Reduce the simultaneous demand from
supply — make sure a dedicated supply
to mixer.
Contact Customer Service for advice on
flow regulators.
Clean – refer to
‘Flushing Procedure’
.
Turn the temperature control clockwise.
(Override the max. temperature stop if
necessary).
Turn the temperature control clockwise.
(Override the max. temperature stop if
necessary).
Make sure heating cylinder is set to
maximum hot water output.
Contact Triton Customer Service for
advice on flow regulators.
Clean – refer to
‘Flushing Procedure’
.
Check water elsewhere in house and if
necessary contact local water company.
Inspect the flow regulators (if fitted) and
the check valves – refer to
‘Flushing
Procedure’
. Clean if necessary.
Clean showerhead.
Reduce the simultaneous demand —
make sure a dedicated supply to mixer.
Make sure service valves are fully open.
Turn off the shower and consult a
competent plumber or contact Triton
Customer Service.
Turn off the shower and consult a
suitably competent plumber.
Renew cartridge (internal seals are not
serviceable).
1.1.1
1.2.1
1.3.1
1.4.1
1.5.1
2.1.1
2.2.1
2.3.1
2.4.1
2.5.1
3.1.1
3.2.1
3.3.1
3.4.1
3.4.2
4.1.1
5.1.1
6.1.1
Not enough cold
water flowing
through shower.
Increase in the
ambient cold
water
temperature.
High volume of
cold water
drawn off
elsewhere.
Excessive flow
rate.
Dirty check
valves.
Not enough hot
water flowing
through shower.
Decrease in the
ambient cold
water
temperature.
Not enough hot
water supplied
from the heating
appliance.
Excessive flow
rate.
Dirty check
valves.
Water supplies
cut off.
Shower unit
blocked.
Showerhead
blocked.
Reduced flow
rate when other
outlets in use.
Water supply
blocked or
restricted.
Blockage in
pipework.
Pipework not
flushed before
connecting the
unit(‘O’ rings
damaged).
1.1
1.2
1.3
1.4
1.5
2.1
2.2
2.3
2.4
2.5
3.1
3.2
3.3
3.4
4.1
5.1
6.1
Water too hot.
Water too cold.
Water does not
flow or shower
pattern collapses
when another
outlet is turned on.
Water too cold or
too hot.
Water does not
flow or shower
pattern collapses
when another
outlet is turned on.
Shower will not
shut off.
1
2
3
4
5
6
Y-004-A
Any maintenance or repair to the shower must be carried out by a suitably
qualified person