The site must be prepared by the customer or an agent who is fully conversant with the requirements of install-
ing ATM equipment. The responsibility for ensuring that the site is prepared in compliance with this document
remains with the customer.
For information and guidance only, a list is provided to outline the general matters for which the customer is re-
sponsible. This list is not intended to be comprehensive and in no way modifies, alters, or limits the responsibility
of the customer for all aspects of site preparation. These procedures should be carried out prior to the arrival of
the ATM.
1. Location of the ATM and site preparation. Ensure access is not hindered by cabinet placement.
2. Site wiring (power and communications).
3. Location of any other equipment that may cause electrical, electromagnetic, or head induced interference.
4. Installation of all communications cables, wall jacks, and other associated hardware.
5. Installation of any necessary power distribution boxes, conduits, and grounds.
6. Make any required building alterations to meet wiring and site requirements.
7. Ensure all applicable codes, regulations, and laws are adhered to.
8. Ensure environmental requirements of the unit are met.
9. Install ATM terminal in accordance with ADA/DDA/CSA accessibility regulations for the state or country of
installation.
site preparation
Site Preparation Checklist
Select site and design floor plan.
Plan installation and accessory needs before starting. Ensure instal-
lation accessories are available.
Check floor plan and make necessary alterations.
Ensure all environmental conditions of the unit are met.
Check communication line requirements.
Install and test communications lines.
Install and test all required electrical fixtures/power outlets.
Establish contractor and vendor schedules.
Plan operator training exercises (optional).
1. Temperature and humidity must fall within the following ranges for ARGO FT operation:
Temperature (Exterior)
—
-30°F to 0°F
—
0°F to 40°F
—
40°F to 122°F
Humidity (Interior, Non-Condensing)
—
10% - 20%
—
10% - 30%
—
20% - 80% (20% - 70% for polymer banknotes)
Temperature (Interior)
—
70°F to 80°F
—
60°F to 80°F
—
50°F to 104°F