Inclusive Bar Mixer Shower
10
FITTING THE MIXER CONTROLS
The mixer controls will need to be fitted before
commissioning can be carried out.
Temperature Control -
(fig.11)
Fit the maximum temperature stop. The
orientation is shown in
fig.11
.
Fit the temperature control (right hand side)
ensuring that the temperature override engages
with the max temperature stop. Once in place, fit
the retaining screw.
Flow Control -
(fig.12)
To fit the flow control (left hand side), the
flow control cartridge needs to be turned fully
clockwise until it stops.
NOTE:
The flow control graphic (styles of this
may vary) should be positioned so that the
front edge of it is at the 12 o’clock position.
The remainder of the graphic should run
towards you.
If fitted correctly, the graphic and flow control
should now be sitting in the designed OFF
position.
Once in place, fit the retaining screw.
Do not fit the end trims until the commissioning
procedure has been carried out and the
temperature range checked.
LEAK TESTING THE MIXER
IMPORTANT: Flush out the pipework in
accordance with Water Regulations and
Bylaws.
Fit the hose to the outlet
without the shower
head fitted
and direct it towards the waste
outlet.
Open the water isolating valves to the shower
and check for leaks.
If any leaks are found, rectify them before
carrying out the commissioning procedure.
Fig.12
Front of
graphic in the
12 o’clock
position
Flow control graphic
(style may vary)
Fig.11
Marker to be
located at the 12
o’clock position
when fitted to valve.
Turn the flow
control fully
clockwise
Maximum
temperature
stop