background image

Inclusive Bar Mixer Shower

11

Fig.13

Mixer outlet

Flow regulator

Flow regulator

Water flow

Angled top 

section

Top

Note:

 the flow regulator 

must

 be fitted with the 

angled top facing the outlet flow of water.

COMMISSIONING

Start the water flow by rotating the flow control 
(left hand side) anti-clockwise.
Make sure that the hot and cold water supplies 
are fully open and at (or near to) their design 
temperature and pressures, and are within the 
requirements as stated on 

page 2 & 12.

Make sure the temperature control (right hand 
side) is at the maximum temperature setting 

WITHOUT

 operating the maximum temperature 

override button.
Allow the shower to run at this maximum 
temperature setting until the water temperature 
has stabilised. 
Rotate the temperature control until your desired 
maximum showering temperature is reached.

NOTE:

 

If your desired temperature is above the 

maximum temperature stop limit, please see the

 

ADJUSTING THE MAXIMUM TEMPERATURE 
STOP SETTING 

section.

A final temperature check 

SHOULD

 be made on-

site to guarantee user safety, and that the mixer 
falls within recommended maximum mixed 
water outlet temperatures - 

as stated on Page 

12.

FLOW REGULATION

A flow regulator is supplied for use with high-
pressure water systems. It may be fitted with 
any of the systems listed to reduce flow rate and 
assist economy.
Fit the flow regulator into the outlet fitting as 
shown in 

fig.13.

Содержание ASTI LEVER

Страница 1: ...ISTER BY TEL 024 7637 8321 INSTALLATION AND OPERATING INSTRUCTIONS Please read this book thoroughly and familiarise yourself with all instructions before commencing installation and keep it for future...

Страница 2: ...11 FLOW REGULATION 11 TEMPERATURE ADJUSTMENT RANGE 12 ADJUSTING THE MAXIMUM TEMPERATURE SETTING 12 OPERATING THE SHOWER 13 DIMENSIONS 14 APPROVALS 15 PRODUCT FLOW RATES 15 MAINTENANCE 16 FAULT FINDIN...

Страница 3: ...s fitting book regarding the product and installation are approximate All kits are for illustration purposes only and are not supplied unless otherwise stated MAIN COMPONENTS Fig 1 A Thermostatic bar...

Страница 4: ...mixer shower Water Minimum Flow Rate For best performance within the specified running pressure range a minimum flow of 8 litres per minute should be available to both inlets Water Temperature Requir...

Страница 5: ...is not flushed through before fitting Commercial Applications It is recommended that for all commercial applications easily accessible in line filters are used to aid maintenance Hard Water Areas a If...

Страница 6: ...t pressures as shown please refer to the pump installation guide to establish the minimum head requirements for automatic operation of the pump Hot water cylinder Cold supply Hot supply Alternative su...

Страница 7: ...systems with no cold water take off after the appliance reducing valve it will be necessary to fit an additional drop tight pressure reducing valve when the mains pressure is over 5 bar The drop tigh...

Страница 8: ...running An expansion vessel MUST be fitted and regularly maintained to ensure the unit is not damaged by excess pressures This may already be installed externally or internally within the thermal sto...

Страница 9: ...work to the shower area having decided on the position of the shower and direction of pipe entry for example rising falling or rear entry The hot and cold water pipes should be securely attached withi...

Страница 10: ...bow fittings in solid wall installations The inlet centres on the variable connectors have a degree of adjustment to allow for misalignment of pipe work The hot and cold supply pipes MUST be anchored...

Страница 11: ...ess fig 9 Screw the supplied cover trims onto the fittings until tight to the wall fig 10 FITTING THE SHOWER IMPORTANT Make sure that all supply pipework has been flushed through before fitting the mi...

Страница 12: ...nder of the graphic should run towards you If fitted correctly the graphic and flow control should now be sitting in the designed OFF position Once in place fit the retaining screw Do not fit the end...

Страница 13: ...m temperature override button Allow the shower to run at this maximum temperature setting until the water temperature has stabilised Rotate the temperature control until your desired maximum showering...

Страница 14: ...mperatures must never exceed 46 C at terminal fitting The British Burns Association recommends 37 to 37 5 C as a comfortable bathing temperature for children In premises covered by the Care Standards...

Страница 15: ...s flowing fig 16 To adjust the water temperature rotate the temperature control right hand side clockwise for a cooler shower or anti clockwise for a hotter shower fig 17 To overcome the maximum tempe...

Страница 16: ...Inclusive Bar Mixer Shower 14 290 00 1 2 BSP 180 00 150 00 3 4 BSP 4 0 5 0 56 25 DIMENSIONS All dimensions regarding the product and installation are approximate...

Страница 17: ...ure shower only PRODUCT FLOW RATES Flow Rate l m 5 0 6 9 9 0 10 9 12 0 17 5 25 5 31 5 36 5 41 0 Pressure bar 0 1 0 2 0 3 0 4 0 5 1 0 2 0 3 0 4 0 5 0 Conditions for test Inlet temperatures comply with...

Страница 18: ...itially check the filters for debris once every three months and clean if necessary b Perform a thermal shut off test every three months and check the maximum temperature setting See the Commissioning...

Страница 19: ...ocked or restricted 2 6 Flow regulator not fitted HP systems only 3 1 Flow regulators not fitted 1 1 1 Refer to the Commissioning section 1 2 1 Reposition temperature control knob 1 3 1 Reposition tem...

Страница 20: ...the inlet filters Clean if necessary 4 3 1 Turn off the shower and consult a suitably competent plumber 4 4 1 Clean shower head 4 5 1 Reduce the simultaneous demand 4 5 2 Make sure stop service valves...

Страница 21: ...Inclusive Bar Mixer Shower 19...

Страница 22: ...Inclusive Bar Mixer Shower 20...

Страница 23: ...Inclusive Bar Mixer Shower 21...

Страница 24: ...ent of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information cont...

Отзывы: