- - XM572-V1.0-NR
5
Before mounting make sure that the installation area can hold a minimum point load of 10 times the device’s
weight.
Connect the fixture to the mains with the power plug.
Installation via the Omega holders
Screw one clamp each via a M12 screw and nut directly into the bracket of the scanner. Pull the safety-chain
through the bracket of the base and over the trussing system or a safe fixation spot.
DMX-512 control connection
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the
male 3-pin XLR input of the moving head. You can chain multiple
Moving head together through serial linking. The cable needed should be two core, screened cable with XLR
input and output connectors. Please refer to the diagram below.
Address 1 Address 10 Address 19
DMX-512 connection with DMX terminator
For installations where the DMX cable has to run a long distance or is in an electrically noisy environment,
such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing corruption of
the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120
Ω
resistor
connected between pins 2 and 3,which is then plugged into the output XLR socket of the last fixture in the
chain. Please see illustrations below.