ERROR MESSAGE
When you turn on the fixture, it will make a reset at first. The display may show“Err channel is XX” while
there are problems with one or more channels. “XX” stands for channel 1, 2, 3, 5, 6 who has the testing sensor
for positioning. For example, when the display shows “02 Er”, it means there is some error in channel 2. If
there are some errors on channel 1, channel 2, channel 3 at the same time, you may see the error message “01
Er”, “02 Er”, “03 Er” flash repeated for 2 times, and then the fixture will generate a second reset. If the fixture
remain error message after performing reset more than 2 times, only the channels which have errors can not
work properly, others can work as usual. Please contact with dealer or manufacturer for service, self repair is
not allowed.
Color Wheel 1- movement Er
(COLOR WHEEL 1-yoke movement error) This message will appear after the reset of the fixture if the yoke’s
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or
its driving IC on the main PCB). The PAN-
movement is not located in the default position after the reset.
Rotating gobos - movement Er
(ROTATING GOBOS-yoke movement error) This message will appear after the reset of the fixture if the
yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is
defective (or its driving IC on the main PCB). The PAN-
movement is not located in the default position after
the reset.
Gobos rotation - movement Er
(GOBOS ROTATION -yoke movement error) This message will appear after the reset of the fixture if the
yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is
defective (or its driving IC on the main PCB). The PAN-
movement is not located in the default position after
the reset.
CLEANING AND MAINTENANCE
The following points have to be considered during the inspection:
1) All screws for installing the devices or parts of the device have to be tightly connected and must not be
corroded.
2) There must not be any deformations on the housing, color lenses, fixations and installation spots (ceiling,
suspension, trussing).
Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances.
The electric power supply cables must not show any damage, material fatigue or sediments.
Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and
any safety problems have to be removed.
In order to make the lights in good condition and extend the life time, we suggest a regular
cleaning to the lights.
1) Clean the inside and outside lens each week to avoid the weakness of the lights due to
accumulation of dust.
2) Clean the fan each week.
3) To make sure the smooth gobo rotation, we suggest adding proper lube to the wheel each
three month, avoiding the excessive lube splashes during the gobo rotating.
4) A detailed electric check by approved electrical engineer each three month, make sure that
the circuit contacts are in good condition, prevent the poor contact of circuit from
overheating.
We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never use alcohol or