background image

                                              -    -                                XM572-V1.0-NR 

16

ERROR MESSAGE 

When you turn on the fixture, it will make a reset at first. The display may show“Err channel is XX”   while 
there are problems with one or more channels. “XX” stands for channel 1, 2, 3, 5, 6 who has the testing sensor 
for positioning. For example, when the display shows “02 Er”, it means there is some error in channel 2. If 
there are some errors on channel 1, channel 2, channel 3 at the same time, you may see the error message “01 
Er”, “02 Er”, “03 Er” flash repeated for 2 times, and then the fixture will generate a second reset. If the fixture 
remain error message after performing reset more than 2 times, only the channels which have errors can not 
work properly, others can work as usual. Please contact with dealer or manufacturer for service, self repair is 
not allowed. 
 

Color Wheel 1- movement Er 

(COLOR WHEEL 1-yoke movement error) This message will appear after the reset of the fixture if the yoke’s 
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or 
its driving IC on the main PCB). The PAN-

 

movement is not located in the default position after the reset. 

 
 

Rotating gobos - movement Er 

(ROTATING GOBOS-yoke movement error) This message will appear after the reset of the fixture if the 
yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is 
defective (or its driving IC on the main PCB). The PAN-

 

movement is not located in the default position after 

the reset. 
 

Gobos rotation - movement Er 

(GOBOS    ROTATION -yoke movement error) This message will appear after the reset of the fixture if the 
yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is 
defective (or its driving IC on the main PCB). The PAN-

 

movement is not located in the default position after 

the reset. 
 

CLEANING AND MAINTENANCE 

The following points have to be considered during the inspection: 
1) All screws for installing the devices or parts of the device have to be tightly connected and must not be 
corroded. 
2) There must not be any deformations on the housing, color lenses, fixations and installation spots (ceiling, 
suspension, trussing). 
Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances. 
The electric power supply cables must not show any damage, material fatigue or sediments.   
Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and 
any safety problems have to be removed. 
 

 

 
In order to make the lights in good condition and extend the life time, we suggest a regular 
cleaning to the lights.

 

1)  Clean the inside and outside lens each week to avoid the weakness of the lights due to 

accumulation of dust.

 

2)   Clean the fan each week.

 

3)   To make sure the smooth gobo rotation, we suggest adding proper lube to the wheel each 

three month, avoiding the excessive lube splashes during the gobo rotating.

 

4)   A detailed electric check by approved electrical engineer each three month, make sure that 

the circuit contacts are in good condition,    prevent the poor contact of circuit from 
overheating. 

 

 

We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never use alcohol or 

Содержание WALLY SC 20

Страница 1: ...PROFESSIONAL SCANNER USER MANUAL WALLY SC 20 KEEP THIS MANUAL FOR FUTURE NEEDS...

Страница 2: ......

Страница 3: ...pack the device Inside the box you should find 1 One XLR connection cable 2 One power cable 3 One safety rope 4 Manual Features LED type SST 50 Extremely Long Life 100 000 hr and lower power consumpti...

Страница 4: ...subject to warranty The dealer will not accept liability for any resulting defects or problems If the device has been exposed to temperature changes due to environmental changes do not switch it on i...

Страница 5: ...lified person in order to avoid a hazard Please be aware that damages caused by manual modifications to the device are not subject to warranty Keep away from children and non professionals GENERAL GUI...

Страница 6: ...n of the effect has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation The installation must always be secured with a secondary safety...

Страница 7: ...XLR input of the moving head You can chain multiple Moving head together through serial linking The cable needed should be two core screened cable with XLR input and output connectors Please refer to...

Страница 8: ...e In the case of the scanner which is 9 channel fixture you should set the starting address of the first unit to 1 the second unit to 10 9 1 the third to 19 10 9 and so on Note The modes of DMX 512 da...

Страница 9: ...nge DMX address via external controller ALON AU A Automatic Run in Stand Alone AUTO MAST AU M Automatic Run as Master ALON SO A Sound controlled Run in Stand Alone RUN SOUN MAST SO M Sound controlled...

Страница 10: ...s is set to 0 on the controller Select EBOC by pressing UP or DOWN Press ENTER the display shows ON or OFF Press UP to select ON if you wish to enable this function or DOWN to select OFF if you don t...

Страница 11: ...of the selected channel Reverse display With this function you can rotate the display by 180 Select RDIS by pressing UP or DOWN button Press ENTER the display shows ON or OFF Press UP to select ON if...

Страница 12: ...you can adjust the sensitivity of the microphone 1 Select MIC by pressing UP or DOWN button Press ENTER the display shows M XX XX stands for the number from 0 to 99 3 Press ENTER to confirm or Press...

Страница 13: ...version With this function you can display the software version of the device Select VER by pressing UP or DOWN button Press ENTER the display shows V X X X X stands for the version number e g V 1 0 V...

Страница 14: ...t MATI by pressing UP or DOWN button Press ENTER the display shows XXXX X stands for the number of hours Press ENTER to confirm or Press MODE ESC to return to the main menu Lamp running time With this...

Страница 15: ...hange the scene no by pressing UP or DOWN button Press ENTER the display shows C X X stands for the channel no Such as C 01 it means you are editing channel 1 of the selected scene Select the channel...

Страница 16: ...The number of steps can be defined under STEP and the scenes can be called up under RUN INSTRUCTIONS ON USE DMX channel s functions and their values 9 DMX channels Channel Value Function Color Wheel...

Страница 17: ...ovement 8bit 6 0 255 Tilt Movement Shutter strobe 0 31 Shutter closed 32 63 No function shutter open 64 95 Strobe effect slow to fast 96 127 No function shutter open 128 159 Pulse effect in sequences...

Страница 18: ...GOBOS ROTATION yoke movement error This message will appear after the reset of the fixture if the yoke s magnetic indexing circuit malfunction sensor failed or magnet missing or the stepping motor is...

Страница 19: ...AC 208V 50Hz AC 220V 50Hz AC 230V 50Hz AC 240 V 50Hz AC 100V 60Hz AC 120V 60Hz AC 208V 60Hz AC 220V 60Hz AC 230V 60Hz AC 240 V 60Hz Power consumption max 80W Packing dimensions 67 5 x 37 x 33cm Net we...

Отзывы: