background image

8

Wire Mapping Test

b. Cable Open / Too Short

 – When the results 

to the right appear, it means that either the 
cable under test does not have any pins 

directly connected from one end to the other, 
you do not have a cable connected at all (or 
one end is not connected), you do not have 

the appropriate cable type selected in the 
LCD Interface, or the cable is too short to be 

tested.

c. Open Circuit on Near End

 – If there are 

open pins found on the near end of the cable, 
results like those to the right will appear, 
indicating the open pins with an X.

d. Open Circuit on Far End

 – If there are open 

pins found on the far end of the cable, results 
like those to the right will appear, indicating 
the open pins with an X.

e. Open Circuit In-Between Near and Far 

Ends

 – If there is an open circuit in-between 

the near and far ends, results like those to 
the right will appear, indicating the open pins 
with an X on both sides. When there is an 
open circuit in-between the near and far ends 
of the cable, you can locate the position of 
the fault by performing a Cable Length test.

f.  Short Circuit 

– If there is a short circuit, 

results like those to the right will appear to 
indicate the affected pins.

19-04-414-9334DF-EN.indd   8

6/21/2019   8:26:41 AM

Содержание T010-001-K

Страница 1: ...Street Chicago IL 60609 USA www tripplite com support Copyright 2019 Tripp Lite All rights reserved WARRANTY REGISTRATION Register your product today and be automatically entered to win an ISOBAR surg...

Страница 2: ...lt and location of cables Easy to use LCD interface Test cable wiring for open short cross reverse and pairing connection Determine location of open circuit position Determine the length of a cable wh...

Страница 3: ...and fault test 6 UP Button Press to move up through the menu in the LCD interface 7 DOWN Button Press to move down through the menu in the LCD interface 8 ON OFF Button Press to turn the Main Tester...

Страница 4: ...tracing 3 Volume Slider Move it up and down to adjust the volume of the tone generated during cable tracing 4 Test Button Press to send the tone through the cable when performing cable tracing 5 Flas...

Страница 5: ...5 Remote Tester Unit 1 RJ45 Port 2 USB A Port 3 RJ11 Port 4 BNC Port 4 1 3 2 19 04 414 9334DF EN indd 5 6 21 2019 8 26 41 AM...

Страница 6: ...ting Cable Length Used to perform a Cable Length test Scan Cable Used when performing the Wire Tracking function Unit Determine the unit of measurement in which to display length information Calibrati...

Страница 7: ...avigate to the Type option Press the Enter button to toggle between the cable type options until you get to the type of cable you are testing 4 After selecting the cable type navigate to the Wire Mapp...

Страница 8: ...ting the open pins with an X d Open Circuit on Far End If there are open pins found on the far end of the cable results like those to the right will appear indicating the open pins with an X e Open Ci...

Страница 9: ...se to the right i Open Circuit Installed Cable When testing installed cable that connects from the Main Tester unit to a wallplate switch or other device open circuits are indicated by results like th...

Страница 10: ...and press the Enter button to initiate calibration 5 A screen will appear asking if you want to proceed Choose Yes and press the Enter button to proceed with calibration 6 The tester will measure the...

Страница 11: ...of the connected cable followed by the results of the test The possible test results are listed below a Normal Pairing and Length When there are no faults in the cable pairing results like those to t...

Страница 12: ...Menu and select the type of cable you have connected by pressing the Enter button to toggle through the options 3 Once you have selected the cable type navigate to the Scan Cable option and press the...

Страница 13: ...OFF button and continue holding down the UP and DOWN buttons until a menu appears on the screen 3 Scroll down until con1 8 thro appears on the screen then press the ENTER button A similar screen will...

Страница 14: ...appear again 8 Press the DOWN button twice to exit recalibration settings 9 Scroll down and press the ENTER button once Save Off appears on the screen When completed Sys Adj End will appear on the scr...

Страница 15: ...DVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically TRIPP LITE is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data co...

Страница 16: ...16 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 19 04 414 93 34DF_RevB 19 04 414 9334DF EN indd 16 6 21 2019 8 26 42 AM...