13
Recalibration
Note:
Prior to performing recalibration:
• The unit needs to be turned OFF.
• An RJ45 cable must connected to the Main Tester unit and the Remote Tester Unit.
Not doing so will prompt the error message “Invalid remote”.
1.
Press down on the UP, DOWN and ON/OFF buttons simultaneously.
2.
Release the ON/OFF button and continue holding down the UP and
DOWN buttons until a menu appears on the screen.
3.
Scroll down until “con1-8:thro” appears on the
screen, then press the ENTER button. A similar
screen will appear:
4.
Press the ENTER button.
5.
A progress bar with the word “Identify” will
appear on the screen:
6.
Press the ENTER button again. A similar screen
will appear:
L0: 50000
L1: 418967
L2: 1152436
L3: 5972543
-----Identify------
1-2: 125106
3-6: 700008
4-5: 1135720
7-8: 10000000
19-04-414-9334DF-EN.indd 13
6/21/2019 8:26:41 AM