Tripp Lite PowerVerter PVX700 Скачать руководство пользователя страница 26

26

Îáñëóæèâàíèå

Åñëè Âû âîçâðàùàåòå Èíâåðòîð â êîìïàíèþ Tripp Lite, òî, ïîæàëóéñòà, òùàòåëüíî óïàêóéòå åãî, èñïîëüçóÿ
ÎÐÈÃÈÍÀËÜÍÛÉ ÓÏÀÊÎÂÎ×ÍÛÉ ÌÀÒÅÐÈÀË, êîòîðûé ïîñòóïèë âìåñòå ñ áëîêîì. Âëîæèòå ïèñüìî, îïèñûâàþùåå
ñèìïòîìû ïðîáëåìû. Åñëè Èíâåðòîð íàõîäèòñÿ â ïðåäåëàõ ãàðàíòèéíîãî ïåðèîäà, òî âëîæèòå êîïèþ Âàøåé êâèòàíöèé î
ïîêóïêå áëîêà. Äëÿ ïîëó÷åíèÿ îáñëóæèâàíèÿ Âû äîëæíû ïîëó÷èòü îò êîìïàíèè Tripp Lite èëè îò àâòîðèçîâàííîãî
ñåðâèñíîãî öåíòðà Tripp Lite íîìåð Âîçâðàòíîé ìàòåðèàëüíîé àâòîðèçàöèè (RMA - Returned Material Authorization). 

Òåõíè÷åñêîå îáñëóæèâàíèå

Óñòðàíåíèå íåèñïðàâíîñòåé

Âàø Èíâåðòîð íå òðåáóåò íèêàêîãî òåõíè÷åñêîãî îáñëóæèâàíèÿ, îí íå ñîäåðæèò äåòàëåé, îáñëóæèâàåìûõ èëè çàìåíÿåìûõ
ïîëüçîâàòåëåì, íî äîëæåí âñåãäà ïîääåðæèâàòüñÿ â ñóõîì ñîñòîÿíèè. Ïåðèîäè÷åñêè ïðîâåðÿéòå, î÷èùàéòå è ïðè
íåîáõîäèìîñòè çàòÿãèâàéòå âñå êàáåëüíûå ñîåäèíåíèÿ íà áëîêå è íà áàòàðåå.

Ïðèçíàê íåèñïðàâíîñòè

Ïðè÷èíà íåèñïðàâíîñòè

Óñòðàíåíèå íåèñïðàâíîñòè

Ñðàáîòàëà çâóêîâàÿ 

Íèçêîå íàïðÿæåíèå àêêóìóëÿòîðíîé

Âûêëþ÷èòå ïðåîáðàçîâàòåëü è çàâåäèòå ñèãíàëèçàöèÿ. äâèãàòåëü, ÷òîáû 

áàòàðåè (<10,5 Â).

ïîäçàðÿäèòü áàòàðåþ. 

Âûêëþ÷èòå ïðåîáðàçîâàòåëü è óñòðàíèòå ïåðåãðóçêó ïóòåì Ïåðåãðóçêà íà 
âûõîäå ïðåîáðàçîâàòåëÿ. îòêëþ÷åíèÿ îò âûõîäíîé ðîçåòêè ïîòðåáèòåëåé 
áîëüøîé ìîùíîñòè. Íàãðóçêà íå äîëæíà ïðåâûøàòü ìàêñèìàëüíóþ 
íåïðåðûâíóþ âûõîäíóþ ìîùíîñòü âàøåãî ïðåîáðàçîâàòåëÿ 
(ñì. Òåõíè÷åñêèå õàðàêòåðèñòèêè).

Ïðåîáðàçîâàòåëü ÍÅ ÂÊËÞ×ÀÅÒÑß Ïðåîáðàçîâàòåëü àâòîìàòè÷åñêè îòêëþ÷àåòñÿ Âûêëþ÷èòå ïðåîáðàçîâàòåëü è çàâåäèòå äâèãàòåëü, ÷òîáû 
ïðè óñòàíîâêå âêëþ÷àòåëÿ ïèòàíèÿ  èç-çà íèçêîãî íàïðÿæåíèÿ àêêóìóëÿòîðíîé  ïîäçàðÿäèòü 

áàòàðåþ.

â ïîëîæåíèå ON.

áàòàðåè (<10 Â).

Ïðåîáðàçîâàòåëü àâòîìàòè÷åñêè 

Âûêëþ÷èòå ïðåîáðàçîâàòåëü è óñòðàíèòå ïåðåãðóçêó ïóòåì îòêëþ÷åíèÿ îò 

îòêëþ÷àåòñÿ èç-çà ïåðåãðóçêà íà âûõîäå.

âûõîäíîé ðîçåòêè ïîòðåáèòåëåé áîëüøîé ìîùíîñòè. Íàãðóçêà íå äîëæíà 
ïðåâûøàòü ìàêñèìàëüíóþ íåïðåðûâíóþ âûõîäíóþ ìîùíîñòü âàøåãî 
ïðåîáðàçîâàòåëÿ (ñì. Òåõíè÷åñêèå õàðàêòåðèñòèêè).

Ïðåäîõðàíèòåëü ïåðåãîðåë.

Çàìåíèòå åãî ñòàíäàðòíûì àâòîìîáèëüíûì ïðåäîõðàíèòåëåì òàêîãî æå 
íîìèíàëà  (ñì. Òåõíè÷åñêèå õàðàêòåðèñòèêè).

Ïðåîáðàçîâàòåëü íå ïîäàåò ïèòàíèå Íèçêîå íàïðÿæåíèå áàòàðåè óìåíüøàåò

Àêêóìóëÿòîðíàÿ áàòàðåÿ ðàçðÿäèëàñü. Âûêëþ÷èòå ïðåîáðàçîâàòåëü è 

â ïîäñîåäèíåííîå îáîðóäîâàíèå.  âûõîäíóþ ìîùíîñòü ïðåîáðàçîâàòåëÿ.

çàâåäèòå äâèãàòåëü, ÷òîáû ïîäçàðÿäèòü áàòàðåþ.

Ìîäåëü: 

PVX700

Âûõîäíàÿ ìîùíîñòü (ìàêñèìàëüíàÿ íåïðåðûâíàÿ ìîùíîñòü â Âàòòàõ)*:

700

Âûõîäíàÿ ìîùíîñòü (ïèêîâàÿ ìîùíîñòü â Âàòòàõ)**:

1400

Âõîäíîå íàïðÿæåíèå (ïîñòîÿííûé òîê):

Íîìèíàëüíîå íàïðÿæåíèå 12 Â (10 - 15 Â)

Âûõîäíîå íàïðÿæåíèå (ïåðåìåííûé òîê)/×àñòîòà

íîìèíàëüíîå 230 Â / 50 Ãö 

Êðèâàÿ âûõîäíîãî ñèãíàëà:

Ñèíóñîèäà PWM

Ïðåäóïðåäèòåëüíûé ñèãíàë î íèçêîì íàïðÿæåíèè áàòàðåè (Â):

10,5 Â

Ïðåäóïðåäèòåëüíûé ñèãíàë î íàïðÿæåíèè îòêëþ÷åíèÿ (Â):

10 Â

Êîë-âî ðîçåòîê ïåðåìåííîãî òîêà:

1

Çàùèòà öåïè (Ìèíèìàëüíîå ñîïðîòèâëåíèå ïîñòîÿííîãî òîêà)

Ïðåäîõðàíèòåëü íà 125 À (âíåøíèé)

Ìèíèìàëüíûé ðàçìåð êàáåëÿ àêêóìóëÿòîðà:

6 ÀÑÎÏ (4 ìì)

Ìèíèìàëüíûé ðàçìåð êàáåëÿ àêêóìóëÿòîðà:

4 ÀÑÎÏ (5 ìì)

Ðàçìåð êàáåëÿ çàçåìëåíèÿ:

12-18 ÀÑÎÏ (1-2 ìì)

Ìàòåðèàë êîðïóñà: 

Ïðåññîâàííûé àëþìèíèé

* Ìàêñèìàëüíàÿ âûõîäíàÿ ìîùíîñòü (íåïðåðûâíàÿ èëè ïèêîâàÿ) äîñòèãàåòñÿ òîëüêî åñëè àêêóìóëÿòîðíàÿ áàòàðåÿ çàðÿæåíà ïîëíîñòüþ. Çàïóñêàéòå äâèãàòåëü ïî÷àùå, ÷òîáû ïîääåðæèâàòü çàðÿæåííîñòü
áàòàðåè íà äîëæíîì óðîâíå. ** Ïèêîâàÿ âûõîäíàÿ ìîùíîñòü ÿâëÿåòñÿ êðàòêîâðåìåííîé. 

Ïðåæäå ÷åì îáðàùàòüñÿ â ñåðâèñ-öåíòð ïî ïîâîäó ðåìîíòà ïðåîáðàçîâàòåëÿ, ïðîâåäèòå ñëåäóþùèå ïðîâåðêè.

Íàãðóçêà ïîäñîåäèíåííîãî îáîðóäîâàíèÿ
ïðåâûøàåò ìàêñèìàëüíóþ íåïðåðûâíóþ
âûõîäíóþ ìîùíîñòü ïðåîáðàçîâàòåëÿ.

Âûêëþ÷èòå ïðåîáðàçîâàòåëü è óñòðàíèòå ïåðåãðóçêó ïóòåì îòêëþ÷åíèÿ îò
âûõîäíîé ðîçåòêè ïîòðåáèòåëåé áîëüøîé ìîùíîñòèÍàãðóçêà íå äîëæíà
ïðåâûøàòü ìàêñèìàëüíóþ íåïðåðûâíóþ âûõîäíóþ ìîùíîñòü âàøåãî
ïðåîáðàçîâàòåëÿ (ñì. Òåõíè÷åñêèå õàðàêòåðèñòèêè).

Ïîäñîåäèíåííîå îáîðóäîâàíèå
ïîäâåðãàåòñÿ âîçäåéñòâèþ
àóäèî/âèäåîïîìåõ

Ïðîâåðüòå è îáåñïå÷üòå íàäåæíîñòü âñåõ ñîåäèíåíèé.

Èçìåíèòå ïîëîæåíèå àíòåíí îáîðóäîâàíèÿ è ïðåîáðàçîâàòåëÿ.

Íåïëîòíîå ïîäñîåäèíåíèå.<

Àóäèî/âèäåîïîìåõè.

Òåõíè÷åñêèå õàðàêòåðèñòèêè

Содержание PowerVerter PVX700

Страница 1: ...always have battery power to start your vehicle PowerVerter DC to AC Inverter Model PVX700 Input Output 12V DC 230V 50Hz AC 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1212 www tr...

Страница 2: ...atteries of identical voltage age amp hour capacity and type Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated your batteries should not be installed wh...

Страница 3: ...nditions and shuts down the Inverter as a protective measure Turn the ON OFF switch to the OFF position if the alarm sounds See the Operation section for more information 1 2 3 4 5 4 3 5 1 2 Operation...

Страница 4: ...power before you have to recharge your batteries This will give you a rough estimate of how many amp hours of battery power from one or several batteries you should connect to your Inverter NOTE Batt...

Страница 5: ...able Sizing Connect Ground Using a 12 18 AWG 1 2 mm wire directly connect the Main Ground Screw to the vehicle s chassis or earth ground See the Feature Identification section to locate the Main Groun...

Страница 6: ...e product has been assigned a unique series number The series number can be found on the product nameplate label along with all required approval markings and information When requesting compliance in...

Страница 7: ...n de energ a CA Los inversores PowerVerter incluyen caracter sticas avanzadas que protegen su equipo alargando la vida de servicio de su bater a y que aseguran que siempre contar con suficiente energ...

Страница 8: ...as hidr geno explosivo cerca de las bater as si no est n bien ventiladas no debe instalar bater as ya sea para una aplicaci n m vil o estacionaria en un compartimiento sin circulaci n de aire En forma...

Страница 9: ...a y apaga el Inversor como una medida de protecci n Coloque el interruptor ON OFF Encendido Apagado en la posici n OFF Apagado si sonara la alarma Vea la secci n Operaci n para m s informaci n 1 2 3 4...

Страница 10: ...er a antes de tener que recargar sus bater as Esto le dar un estimado grueso de cuantos amperios hora de energ a de bater a de una o varias bater as debe conectar a su inversor NOTA La capacidad de am...

Страница 11: ...e 45 cm 18 de la bater a La capacidad del fusible debe ser igual o mayor que la M nima capacidad de fusible de CC indicada en las especificaciones de su inversor Vea la secci n Especificaciones para r...

Страница 12: ...Completa 1 2 horas 2 4 horas continuos Motor Encendido En Marcha 1 2 Carga Motor Apagado no recomendado 1 hora 2 horas Carga Completa no recomendado no recomendado 1 hora Motor Apagado NOTA Puede max...

Страница 13: ...NEIDAD PARA UN PROP SITO PARTICULAR Algunos estados no permiten limitaciones o exclusiones de las garant as impl citas por lo tanto las limitaciones o exclusiones mencionadas anteriormente pueden no a...

Страница 14: ...manquent de courant CA Les convertisseurs PowerVerter comprennent des caract ristiques perfectionn es qui prot gent votre quipement prolongent la dur e de service de votre batterie et garantissent que...

Страница 15: ...nstaller vos batteries que ce soit pour une application mobile ou stationaire dans un compartiment sans circulation d air Id alement tout compartiment devrait disposer d une ventilation d air ext rieu...

Страница 16: ...tiquement des conditions de surcharge et arr te le convertisseur par mesure de protection Mettre l interrupteur ON OFF en position OFF si l alarme retentit Voir la section Fonctionnement pour plus de...

Страница 17: ...nt que vous ne deviez recharger vos batteries Cela vous donnera une estimation grossi re de la puissance de batterie enA h d une ou de plusieurs batteries que vous devrez brancher votre onduleur REMAR...

Страница 18: ...la batterie Le calibre nominal du fusible doit tre gal ou sup rieur au calibre minimal de fusible CC inscrit dans les sp cifications Voir les sp cifications pour les recommandations de fusible et de b...

Страница 19: ...eure moteur l arr t NOTE Vous pouvez maximiser la puissance de sortie en suivant une ou plus de ces tapes 1 connecter plusieurs batteries au convertisseur 2 garder les batteries pleine charge en faisa...

Страница 20: ...ADAPTATION UNE APPLICATION PARTICULI RE Certaines provinces ou tats ne reconnaissent ni l exclusion ni la limite des garanties implicites les limites ou les exclusions susmentionn es peuvent ne pas co...

Страница 21: ...treet Chicago IL 60609 USA 773 869 1212 www tripplite com 2007 PowerVerter Tripp Lite PowerVerter P PV VX X7 70 00 0 12 230 50 Espa ol Fran ais English 22 27 23 23 24 24 25 26 7 14 1 26 PowerVerter 12...

Страница 22: ...Tripp Lite he 5 Tripp Lite Tripp Lite UPS Uninterruptible Power Supply 22...

Страница 23: ...23 20 ON OFF ON OFF OFF ON OFF OFF ON OFF OFF 1 2 3 4 5 4 3 5 1 2 ON OFF ON ON OFF OFF OFF 1 ON OFF OFF 2 3 4 5 ON OFF ON 1 ON OFF OFF 2 3 4 5 ON OFF ON...

Страница 24: ...24 Tripp Lite 1 1 3 1 3 230 300 75 80 2 1 1 2 3 2 20 55 50 9 30 300 220 20 540 300 140 100 540 1 2 x 540 12 54 54 5 270 Tripp Lite 3 2 1 1 2 3...

Страница 25: ...25 5 mm 4 AWG American Wire Gauge 200 3 5 1 2 mm 12 18 AWG American Wire Gauge Tripp Lite 45 18 12 12 12 1 2 3 5 7 8 8 7 4 5 3 2 2 6 1 12 12 12 CE 45 4 5 12 18 1 2 8 7 6 5 4 3 2 1...

Страница 26: ...26 Tripp Lite Tripp Lite Tripp Lite RMA Returned Material Authorization 10 5 ON 10 PVX700 700 1400 12 10 15 230 50 PWM 10 5 10 1 125 6 4 4 5 12 18 1 2...

Страница 27: ...27 4 4 6 6 8 8 PVX700 1 2 1 2 2 4 1 2 1 2 1 1 2 3 4 5 6 6 4 4 5 Tripp Lite 1 Tripp Lite RMA Tripp Lite Tripp Lite Tripp Lite Tripp Lite 10 TRIPP LITE TRIPP LITE Tripp Lite Tripp Lite Tripp Lite...

Страница 28: ...28 200701124 93 2655 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1212 www tripplite com...

Отзывы: