Feature Identification

Identify the premium features on your specific model and quickly locate instructions on how to maximize their use.

Operating Mode Switch: 

controls Inverter operation. Set this 

2-position slide switch to “ON/REMOTE” to have your Inverter
provide connected equipment with AC power by converting DC
power from an attached battery or remotely monitor and control
the Inverter with the use of an optional remote module. Set
switch to “OFF” when not using connected equipment to pre-
vent battery drain.  

“LOAD” Indicator Lights:

intuitive “traffic light” signals show

approximate equipment load level. See page 4 for instructions
on reading indicator lights.

“BATTERY” Indicator Lights:

intuitive “traffic light” signals

show approximate charge level of your battery. See page 4 for 
instructions on reading indicator lights.

DC Power Terminals:

connect to your battery terminals. See 

page 7 for connection instructions.

Ground Fault Interrupter (GFI) AC Receptacles: 

allow you

to connect equipment that would normally be plugged into a
utility outlet. They feature ground fault interrupter switches that
trip if there is excessive current on the ground safety wire. 

Resettable Circuit Breaker:

protects your Inverter against

damage due to overload. See page 4 for resetting instructions.

Remote Control Module Connector:

allows remote monitoring

and control with an optional module (Tripp Lite model
APSRM4, sold separately). See remote module owner’s manu-
al for connection instructions.

Battery Charge Conserver (Load Sense) Dial:

conserves battery

power by setting the low-load level at which the Inverter auto-
matically shuts off. See page 4 for setting instructions.

Multi-Speed Cooling Fan(s):

quiet, efficient fans prolong

equipment service life.

Main Ground Lug: 

properly grounds the Inverter to vehicle

grounding system or earth ground. See page 7 for connection
instructions.

Low Battery Alarm/Shutdown (internal, not shown):

auto-

matically detects low voltage and shuts down Inverter to preserve
vehicle battery.

Overload Alarm/Shutdown (internal, not shown): 

automatically

detects wattage overload on Inverter outlets and shuts down
Inverter as a protective measure.

Ignition Switch Control Jack (rear panel, not shown):

use to

connect the Inverter to your vehicle’s ignition switch (with user-
supplied cable) in order to automatically control the Inverter
with the vehicle's ignition switch. See Operation section.

1

2

3

4

5

6

7

8

9

10

Front View (750 & 1250 Models)

1

3

2

4

5

6

7

9

10

8

Содержание PowerVerter Plus

Страница 1: ...ion process and a charge conservation setting draw the highest level of performance from your batteries without overtaxing them lengthening their service life An automatic low battery shutdown feature...

Страница 2: ...t well ventilated your batteries should not be installed in a dead air compartment Ideally any compartment would have some ventilation to outside air Sparks may result during final battery connection...

Страница 3: ...rrent on the ground safety wire Resettable Circuit Breaker protects your Inverter against damage due to overload See page 4 for resetting instructions Remote Control Module Connector allows remote mon...

Страница 4: ...se Dial In order to save battery power the Inverter automatical ly shuts off in the absence of any power demand from connected equipment or appliances the electrical load When the unit detects a load...

Страница 5: ...rs you estimate you will operate your equipment exclusively from battery power before you have to recharge your batteries Compensate for inefficiency and wiring losses by multiplying this number by 1...

Страница 6: ...ounting optional WARNING If you choose to mount your Inverter mount it and wire its DC input BEFORE DC battery connection Failure to follow these instructions may lead to personal injury and or damage...

Страница 7: ...n addition to the protection provided by the Inverter s internal fuses NEC article 551 requires that you connect your Inverter s positive DC Terminal s directly to a UL listed fuse s and fuse block s...

Страница 8: ...RPOSE Some states do not permit lim itation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT W...

Страница 9: ...ft 44 ft 56 ft 1000 N R 12 ft 20 ft 31 ft 39 ft 2000 N R N R N R 16 ft 20 ft 2400 N R N R N R 13 ft 16 ft N R Not Recommended NOTE Acceptable power is directly related to cable length i e the shorter...