background image

8PV

Try these remedies for common Inverter problems before calling for assistance. Call Tripp Lite Customer Service at (773) 869-1234 before
returning your unit for service.

Troubleshooting

SYMPTOM

PROBLEMS

CORRECTIONS

No AC Output

Operating Mode Switch is set to “OFF.”

Set Operating Mode Switch to “ON/REMOTE.”

(All Indicator Lights Are OFF)

User-supplied UL-listed external DC input fuses have blown.

Replace fuses.

Red Battery Indicator Light

Unit has shut down due to excessive battery discharge.

Run your engine to raise battery voltage. Check external battery

Is Rapidly Flashing

connections and fuse. Reset by moving Operating Mode Switch

(¼ Second Flashes)

to “OFF.” Wait one minute and switch to “ON/REMOTE.”
If unit remains in shutdown mode after several attempts to reset 
contact Tripp Lite Customer Service for assistance.

Red Load Indicator Light

Unit has shut down due to overload.

Reduce load. Reset by moving Operating Mode Switch to “OFF.”

Is Rapidly Flashing

Wait one minute and switch to “ON/REMOTE.” If unit remains in 

(¼ Second Flashes)

shutdown mode after several attempts to reset contact Tripp Lite 
Customer Service for assistance.

Connected Equipment Experiences

Audio/Video interference.

Reposition equipment antennas and Inverter.

Buzzing Sound Or Picture Distortion

Inverter Output Seems Intermittent

Loose cable connections.

Check and secure all connections.

Operating Mode Switch 

Battery Indicator Lights

Load Indicator Lights

200501058  93-2425

Limited Warranty

Tripp Lite warrants its Inverters to be free from defects in materials and workman-
ship for a period of one year (domestic) or 120 days (export) from the date of retail
purchase by end user.

Tripp Lite’s obligation under this warranty is limited to repairing or replacing (at its
sole option) any such defective products. To obtain service under this warranty you
must obtain a Returned Material Authorization (RMA) number from Tripp Lite or an
authorized Tripp Lite service center. Products must be returned to Tripp Lite or an
authorized Tripp Lite service center with transportation charges prepaid and must
be accompanied by a brief description of the problem encountered and proof of
date and place of purchase. This warranty does not apply to equipment which has
been damaged by accident, negligence or misapplication or has been altered or
modified in any way, including opening of the unit’s casing for any reason. This
warranty applies only to the original purchaser who must have properly regis-
tered the product within 10 days of retail purchase.

EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit lim-
itation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or
exclusion(s) may not apply to the purchaser.

EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE
FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAM-
AGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF
THE POSSIBILITY OF SUCH DAMAGE. Specifically, Tripp Lite is not liable for
any costs, such as lost profits or revenue, loss of equipment, loss of use of equip-
ment, loss of software, loss of data, costs of substitutes, claims by third parties,
or otherwise.

Tripp Lite has a policy of continuous improvement. Specifications are subject to
change without notice.

Service

If you are returning your Inverter to Tripp Lite, please pack it carefully, using the ORIGINAL PACKING MATERIAL that came with the
unit. Enclose a letter describing the symptoms of the problem. If the Inverter is within the warranty period, enclose a copy of your sales
receipt. To obtain service you must obtain a Returned Material Authorization (RMA) number from Tripp Lite or an authorized Tripp Lite
service center.

Your Inverter requires no maintenance and contains no user-serviceable or replaceable parts, but should be kept dry at all times. Periodically
check, clean and tighten all cable connections, as necessary, both at the unit and at the battery.

Maintenance

Warranty Registration

Visit www.tripplite.com/warranty to register the
warranty of your new Tripp Lite product. You'll be
automatically entered into a drawing for a chance
to win a FREE Tripp Lite product!*

* No purchase necessary. Void where prohibited. Some restrictions
apply. See website for details.

This product designed and engineered in the USA.

AC Output Connection

To avoid overloading your Inverter, be sure to match the power requirements of the equipment you plan to run at any one time (add their total
watts) with the output wattage capacity of your Inverter model (see Specifications). When figuring the power requirements of your equip-
ment, do not confuse “continuous” wattage with “peak” wattage ratings. Most electric motors require extra power at start-up (“peak”
wattage) than required to run continuously after start-up, sometimes over 100% more. Some motors, such as in refrigerators and pumps,
start and stop intermittently according to demand, requiring “peak” wattage at multiple, unpredictable times during operation.

• DoubleBoost

Feature

Tripp Lite Inverters deliver up to twice their nameplate rated 
wattage for up to 10 seconds,* providing the extra power 
needed to cold start heavy-duty tools and equipment.

• OverPower

Feature

Tripp Lite Inverters deliver up to 150% of their name
plate rated wattage for up to 1 hour,* providing plenty of reserve
power to reliably support tools and equipment longer.

* Actual duration depends on battery age, battery charge level and ambient temperature.

Содержание PowerVerter Plus

Страница 1: ...ion process and a charge conservation setting draw the highest level of performance from your batteries without overtaxing them lengthening their service life An automatic low battery shutdown feature...

Страница 2: ...t well ventilated your batteries should not be installed in a dead air compartment Ideally any compartment would have some ventilation to outside air Sparks may result during final battery connection...

Страница 3: ...rrent on the ground safety wire Resettable Circuit Breaker protects your Inverter against damage due to overload See page 4 for resetting instructions Remote Control Module Connector allows remote mon...

Страница 4: ...se Dial In order to save battery power the Inverter automatical ly shuts off in the absence of any power demand from connected equipment or appliances the electrical load When the unit detects a load...

Страница 5: ...rs you estimate you will operate your equipment exclusively from battery power before you have to recharge your batteries Compensate for inefficiency and wiring losses by multiplying this number by 1...

Страница 6: ...ounting optional WARNING If you choose to mount your Inverter mount it and wire its DC input BEFORE DC battery connection Failure to follow these instructions may lead to personal injury and or damage...

Страница 7: ...n addition to the protection provided by the Inverter s internal fuses NEC article 551 requires that you connect your Inverter s positive DC Terminal s directly to a UL listed fuse s and fuse block s...

Страница 8: ...RPOSE Some states do not permit lim itation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT W...

Страница 9: ...ft 44 ft 56 ft 1000 N R 12 ft 20 ft 31 ft 39 ft 2000 N R N R N R 16 ft 20 ft 2400 N R N R N R 13 ft 16 ft N R Not Recommended NOTE Acceptable power is directly related to cable length i e the shorter...