Important Safety Instructions

SAVE THESE  INSTRUCTIONS!

This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite Inverters.

Location Warnings

• Install your Inverter in a location or compartment in your vehicle that minimizes exposure to heat, dust, direct sunlight and moisture. 

Flooding the unit with water will cause it to short circuit and could cause personal injury due to electric shock.

• Leave a minimum of 2" clearance at front and back of the Inverter for proper ventilation. To avoid overheating the Inverter, any 

compartment that contains the Inverter must be properly ventilated with adequate outside air flow. The heavier the load of connected 
equipment, the more heat will be generated by the unit.

• Do not install the Inverter directly near magnetic storage media, as this may result in data corruption.
• Do not install near flammable materials, fuel or chemicals.

Battery Connection Warnings

• Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type.
• Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated, your batteries should not be 

installed in a “dead air” compartment. Ideally, any compartment would have some ventilation to outside air. 

• Sparks may result during final battery connection. Always observe proper polarity as batteries are connected.
• Do not allow objects to contact the DC input terminals. Do not short or bridge these terminals together. Serious personal injury 

or property damage could result.

Ground Connection Warnings

• Safe operation requires connecting the Inverter's Main Ground Lug directly to the frame of the vehicle or earth ground.

Equipment Connection Warnings

• 

Do not use a Tripp Lite Inverter in life support or healthcare applications where a malfunction or failure of a Tripp Lite 
Inverter could cause failure of, or significantly alter the performance of, a life support device or medical equipment.

• You may experience uneven performance results if you connect a surge suppressor, line conditioner or UPS system to the output of 

the Inverter.

Operation Warnings

• Your Inverter does not require routine maintenance.
• Potentially lethal voltages exist within the Inverter as long as the battery supply is connected. During any service work, the battery 

supply should therefore be disconnected.

• Do not connect or disconnect batteries while the Inverter is operating from the battery supply. Dangerous arcing may result.

2PV

Содержание PowerVerter Plus

Страница 1: ...ion process and a charge conservation setting draw the highest level of performance from your batteries without overtaxing them lengthening their service life An automatic low battery shutdown feature...

Страница 2: ...t well ventilated your batteries should not be installed in a dead air compartment Ideally any compartment would have some ventilation to outside air Sparks may result during final battery connection...

Страница 3: ...rrent on the ground safety wire Resettable Circuit Breaker protects your Inverter against damage due to overload See page 4 for resetting instructions Remote Control Module Connector allows remote mon...

Страница 4: ...se Dial In order to save battery power the Inverter automatical ly shuts off in the absence of any power demand from connected equipment or appliances the electrical load When the unit detects a load...

Страница 5: ...rs you estimate you will operate your equipment exclusively from battery power before you have to recharge your batteries Compensate for inefficiency and wiring losses by multiplying this number by 1...

Страница 6: ...ounting optional WARNING If you choose to mount your Inverter mount it and wire its DC input BEFORE DC battery connection Failure to follow these instructions may lead to personal injury and or damage...

Страница 7: ...n addition to the protection provided by the Inverter s internal fuses NEC article 551 requires that you connect your Inverter s positive DC Terminal s directly to a UL listed fuse s and fuse block s...

Страница 8: ...RPOSE Some states do not permit lim itation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT W...

Страница 9: ...ft 44 ft 56 ft 1000 N R 12 ft 20 ft 31 ft 39 ft 2000 N R N R N R 16 ft 20 ft 2400 N R N R N R 13 ft 16 ft N R Not Recommended NOTE Acceptable power is directly related to cable length i e the shorter...