background image

4R

Operation

Switch Modes

After configuring, mounting and connecting your Inverter/Charger,
you are able to operate it by switching between the following
operating modes as appropriate to your situation:

AUTO/REMOTE:

Switch to this mode when you

need constant, uninterrupted AC power for connected
appliances and equipment. The Inverter/Charger will
continue to supply AC power to connected equipment
and to charge your connected batteries while utility-
or generator-supplied AC power is present. Since the
inverter is ON (but in Standby) in this mode, it will automatically
switch to your battery system to supply AC power to connected
equipment in the absence of a utility/generator source or in
over/under voltage situations. “AUTO/REMOTE” also enables an
optional remote control module (Tripp Lite model APSRM4, sold
separately) to function when connected to the unit.

CHARGE ONLY

: Switch to this mode when you

are not using connected appliances and equipment in
order to conserve battery power by disabling the
inverter. The Inverter/Charger will continue to
supply AC power to connected equipment and
charge connected batteries while utility- or generator-supplied AC
power is present. However, since the inverter is OFF in this mode, it
WILL NOT supply AC power to connected equipment in the
absence of a utility/generator source or in over/under voltage
situations.

OFF (most models): 

Switch to this mode to shut

down the Inverter/Charger completely, preventing
the inverter from drawing power from the batteries,
and preventing utility AC from passing through to
connected equipment or charging the batteries. Use
this switch to automatically reset the unit if it shuts down due to
overload or overheating. First remove the excessive load or allow
the unit to sufficiently cool (applicable to your situation). Switch to
“OFF”, then back to “AUTO/REMOTE” or “CHARGE ONLY” as
desired. If unit fails to reset, remove more load or allow unit to cool
further and retry. Use an optional remote control module (Tripp Lite
model APSRM4, sold separately) to reset unit due to overload and
overtemperature. 

DC OFF (select models):

De-energizes unit and connects AC 

OUT

to AC 

IN

.

Indicator Lights

Your Inverter/Charger (as well as an optional Tripp Lite Remote
Control Module, sold separately) is equipped with a simple,
intuitive, user-friendly set of indicator lights. These easily-
remembered “traffic light” signals will allow you, shortly after first
use, to tell at a glance a wide variety of operating details.

“LINE Green LED”:

If the operating mode switch

is set to “AUTO/REMOTE”, this light will
ILLUMINATE CONTINUOUSLY

when your

connected equipment is receiving continuous AC
power supplied from a utility/generator source.

If the operating mode switch is set to “CHARGE ONLY”, this light
will BLINK to alert you that the unit’s inverter is OFF and will NOT
supply AC power in the absence of a utility/generator source or in
over/under voltage situations.

“INV” (Inverting) Yellow LED: 

This light will

ILLUMINATE CONTINUOUSLY

whenever

connected equipment is receiving battery-supplied,
inverted AC power (in the absence of a
utility/generator source or in over/under voltage
situations). This light will be off when AC power is supplying the
load. This light will BLINK to alert you if the load is less than the
Battery Charge Conserver (Load Sense) setting.

“LOAD” Red LED: 

This red light will

ILLUMINATE CONTINUOUSLY whenever the
inverter is functioning and the power demanded by
connected appliances and equipment exceeds 100%
of load capacity. The light will BLINK to alert you
when the inverter shuts down due to a severe overload or
overheating. If this happens, turn the operating mode switch “OFF”;
remove the overload and let the unit cool. You may then turn the
operating mode switch to either “AUTO/REMOTE” or “CHARGE
ONLY” after it has adequately cooled. This light will be off when
AC power is supplying the load. 

“BATT VOLTAGE” LEDs: 

If the operating mode switch is in the

"AUTO/REMOTE" or "Charge Only" position, the LEDs indicate
the approximate charge level and voltage of your connected battery
bank and alert you to several fault conditions. See Chart for charge
and voltage levels.

LED Function with Switch in “AUTO/REMOTE” or
“CHARGE ONLY” Position

Approximate Battery Charge Level*

LEDs

Battery Capacity

Illuminated

(Charging/Discharging)

Green

91%–Full

Green & Yellow

81%–90%

Yellow

61%–80%

Yellow & Red

41%–60%

Red

21%–40%

All three lights off

1%–20%

Flashing red

0% (Inverter 
shutdown)**

* Charge levels listed are approximate. Actual conditions vary 
depending on battery condition and load. ** Inverter shutdown protects battery against damage
due to  excessive discharge.

Fault Condition

LEDs

Fault 

Illuminated

Condition

All three lights 

Excessive discharge 

flash slowly*

(Inverter shutdown)

All three lights 

Overcharge (Charger 

flash quickly**

shutdown)

*Approximately ½ second on, ½ second off. See Troubleshooting section. Inverter shutdown
protects battery against damage due to excessive discharge.** Approximately ¼ second on, ¼
second off. Charger shutdown protects battery against damage due to overcharge. May also
indicate a battery charger fault exists. See Troubleshooting section.

1

2

3

4

5

6

7

1

2

1

2

3

4

5

6

7

1

2

Содержание PowerVerter 93-2642

Страница 1: ...lt In ISOBAR Surge Protection Automatic Overload Protection Ideal Output for All Loads Frequency Controlled Output Automatic Load Switching Balanced Load Sharing Better for Your Batteries Faster Batte...

Страница 2: ...e hydrogen gas can accumulate near batteries if they are not kept well ventilated your batteries should not be installed whether for a mobile or stationary application in a dead air compartment Ideall...

Страница 3: ...e Circuit Breaker protect your Inverter Charger against damage due to charger failure See Operation section for resetting instructions Remote Control Module Connector allows remote monitoring and cont...

Страница 4: ...details LINE Green LED If the operating mode switch is set to AUTO REMOTE this light will ILLUMINATE CONTINUOUSLY when your connected equipment is receiving continuous AC power supplied from a utility...

Страница 5: ...d of the unit Wait one minute then switch operating mode switch back to either AUTO REMOTE or CHARGE ONLY Select Low AC Input Voltage Point for Switching to Battery OPTIONAL Switch Voltage Position 10...

Страница 6: ...it The figures show how to set your DIP Switches for charger limiting B1 B2 Set Battery Charging Amps OPTIONAL Check specifications for your unit s high and low charging amp options By setting on high...

Страница 7: ...module Connect Battery Temperature Sensing Cable OPTIONAL The battery temperature sensing function prolongs battery life by adjusting the charge float voltage level based on battery temperature Conne...

Страница 8: ...ttery voltage 12 to determine the DC amps required STEP 3 Estimate Battery Amp Hours Required for operation unsupported by the alternator Multiply the DC amps required from step 2 above by the number...

Страница 9: ...ide weather conditions Using the measurements from the diagram install two user supplied 6 mm fasteners into a rigid horizontal surface leaving the heads slightly raised Slide the Inverter Charger for...

Страница 10: ...listed fuse s and fuse block s within 18 inches of the battery The fuse s rating must equal or exceed the Minimum DC Fuse Rating listed in your Inverter Charger s specifications See Specifications fo...

Страница 11: ...ug on the unit In any case the incoming conduit must be bonded to earth or vehicle ground and the incoming conduit must be bonded to the outgoing conduit 1 2 3 4 5 AC Input Output Connection HOT IN NE...

Страница 12: ...you will need to manually reset the unit by moving the Operating Mode Switch to OFF for two seconds then returning it to AUTO REMOTE False reading due to undersized or Use sufficient size DC cable suf...

Страница 13: ...1111 W 35th Street Chicago IL 60609 USA 773 869 1234 USA 773 869 1212 International www tripplite com...