2R

Important Safety Instructions

Caution: If your Inverter/Charger is mounted in a location that lack proper ventilation, the surface of the metal
enclosure could become hot. Allow to cool before touching. If the Inverter/Charger must be installed in a location
that lacks proper ventilation, mount the unit in such a way that the top of the metal enclosure will not be subjected
to accidental contact during operation.

SAVE THESE  INSTRUCTIONS!

This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite
Inverter/Chargers.

Location Warnings

• Although your Inverter/Charger is moisture resistant, it is NOT waterproof. Flooding the unit with water will cause it to short circuit 

and could cause personal injury due to electric shock. Never immerse the unit, and avoid any area where standing water might 
accumulate. Mounting should be in the driest location available.

• Leave a minimum of 2" clearance at front and back of the Inverter/Charger for proper ventilation. To avoid automatic Inverter/Charger

shutdown due to overtemperature, any compartment that contains the Inverter/Charger must be properly ventilated with adequate 
outside air flow. The heavier the load of connected equipment, the more heat will be generated by the unit.

• Do not install the Inverter/Charger directly near magnetic storage media, as this may result in data corruption.

• Do not install near flammable materials, fuel or chemicals.

Battery Connection Warnings

• The Inverter/Charger will not operate (with or without utility power) until batteries are connected.

• Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type.

• Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated, your batteries should not be 

installed (whether for a mobile or stationary application) in a “dead air” compartment. Ideally, any compartment would have some 
ventilation to outside air. 

• Sparks may result during final battery connection. Always observe proper polarity as batteries are connected.

• Do not allow objects to contact the two DC input terminals. Do not short or bridge these terminals together. Serious personal injury 

or property damage could result.

Equipment Connection Warnings

Do not use a Tripp Lite MRV Inverter/Charger in life support or healthcare applications where a malfunction or failure of a 
Tripp Lite MRV Inverter/Charger could cause failure of, or significantly alter the performance of, a life support device or
medical equipment.

• You may experience uneven performance results if you connect a surge suppressor, line conditioner or UPS system to the output of 

the Inverter/Charger.

• Tripp Lite recommends wiring the AC output to a GFCI protector (ground fault circuit interrupter).

• The main grounding lug should be connected to the vehicle chassis with an 8 AWG wire (minimum).

Operation Warnings

• Your Inverter/Charger does not require routine maintenance. Do not open the device for any reason. There are no user serviceable parts inside.

• Potentially lethal voltages exist within the Inverter/Charger as long as the battery supply and/or AC input are connected. During any 

service work, the battery supply and AC input connection (if any) should therefore be disconnected.

• Do not connect or disconnect batteries while the Inverter/Charger is operating in either inverting or charging mode. Operating Mode 

Switch should be in the OFF position. Dangerous arcing may result.

Caution: Some models have a failsafe AC pass-through feature where the AC output will be live (if AC input is available) 
even though the operating mode switch is set to DC OFF.

Содержание PowerVerter 93-2642

Страница 1: ...lt In ISOBAR Surge Protection Automatic Overload Protection Ideal Output for All Loads Frequency Controlled Output Automatic Load Switching Balanced Load Sharing Better for Your Batteries Faster Batte...

Страница 2: ...e hydrogen gas can accumulate near batteries if they are not kept well ventilated your batteries should not be installed whether for a mobile or stationary application in a dead air compartment Ideall...

Страница 3: ...e Circuit Breaker protect your Inverter Charger against damage due to charger failure See Operation section for resetting instructions Remote Control Module Connector allows remote monitoring and cont...

Страница 4: ...details LINE Green LED If the operating mode switch is set to AUTO REMOTE this light will ILLUMINATE CONTINUOUSLY when your connected equipment is receiving continuous AC power supplied from a utility...

Страница 5: ...d of the unit Wait one minute then switch operating mode switch back to either AUTO REMOTE or CHARGE ONLY Select Low AC Input Voltage Point for Switching to Battery OPTIONAL Switch Voltage Position 10...

Страница 6: ...it The figures show how to set your DIP Switches for charger limiting B1 B2 Set Battery Charging Amps OPTIONAL Check specifications for your unit s high and low charging amp options By setting on high...

Страница 7: ...module Connect Battery Temperature Sensing Cable OPTIONAL The battery temperature sensing function prolongs battery life by adjusting the charge float voltage level based on battery temperature Conne...

Страница 8: ...ttery voltage 12 to determine the DC amps required STEP 3 Estimate Battery Amp Hours Required for operation unsupported by the alternator Multiply the DC amps required from step 2 above by the number...

Страница 9: ...ide weather conditions Using the measurements from the diagram install two user supplied 6 mm fasteners into a rigid horizontal surface leaving the heads slightly raised Slide the Inverter Charger for...

Страница 10: ...listed fuse s and fuse block s within 18 inches of the battery The fuse s rating must equal or exceed the Minimum DC Fuse Rating listed in your Inverter Charger s specifications See Specifications fo...

Страница 11: ...ug on the unit In any case the incoming conduit must be bonded to earth or vehicle ground and the incoming conduit must be bonded to the outgoing conduit 1 2 3 4 5 AC Input Output Connection HOT IN NE...

Страница 12: ...you will need to manually reset the unit by moving the Operating Mode Switch to OFF for two seconds then returning it to AUTO REMOTE False reading due to undersized or Use sufficient size DC cable suf...

Страница 13: ...1111 W 35th Street Chicago IL 60609 USA 773 869 1234 USA 773 869 1212 International www tripplite com...

Отзывы: