Tripp Lite Line-Interactive UPS System SMART750USB Скачать руководство пользователя страница 2

3

Quick Installation

Plug the UPS into an outlet
that doesn’t share a circuit
with a heavy electrical load.*

* An air conditioner, refrigerator, etc.

NOTE! after you plug the UPS into a live
AC outlet, the UPS will turn ON automati-
cally. See “ON/OFF” Button description in
the Basic Operation section if you want to
place the UPS in any mode other than ON.

Plug your equipment into 
the UPS.

The

outlets will provide battery backup

and surge protection; plug your computer,
monitor and other critical devices here.*
The

outlets will provide surge protection

only; plug your printer and other non-
essential devices here.

* Your UPS is designed to only support computer equipment.
You will overload the UPS if the total VA ratings for all the
equipment you connect to the (A) outlets exceeds the UPS’s
Output Capacity (see Specifications). To find your equipment’s
VA ratings, look on their nameplates. If the equipment is
listed in amps, multiply the number of amps by 120 to
determine VA. (Example: 1 amp × 120 = 120 VA). If you
are unsure if you have overloaded the (A) outlets, run a
self-test (see “MUTE/TEST” Button description). 

B

A

1

2

1

B

A

2

Important Safety Instructions

2

UPS Location Warnings

• Install your UPS indoors, away from excess moisture or heat, dust or direct sunlight.

• For best performance, keep the indoor temperature between between 32º F and 104º F  

(0º C and 40º C).

• Leave adequate space around all sides of the UPS for proper ventilation.

UPS Connection Warnings

• Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS

into itself; this will damage the UPS.

• Do not modify the UPS’s plug, and do not use an adapter that would eliminate the UPS’s

ground connection.

• Do not use extension cords to connect the UPS to an AC outlet. Your warranty will be

voided if anything other than Tripp Lite surge suppressors are used to connect your UPS 
to an outlet.

• If the UPS receives power from a motor-powered AC generator, the generator must 

provide clean, filtered, computer-grade output.

Equipment Connection Warnings

• Do not use Tripp Lite UPS Systems for life-support applications in which a malfunction 

or failure of a Tripp Lite UPS System could cause failure or significantly alter the 
performance of a life-support device.

• Do not connect surge suppressors or extension cords to the output of your UPS. This may

damage the UPS and will void the surge suppressor and UPS warranties.

Battery Warnings

• Your UPS does not require routine maintenance. Do not open your UPS for any reason.

There are no user-serviceable parts inside.

• Because the batteries present a risk of electrical shock and burn from high short-circuit

current, observe proper precautions. Unplug and turn off the UPS before performing 
battery replacement. Use tools with insulated handles, and replace the existing batteries
with the same number and type of new batteries (Sealed Lead-Acid). Do not open the
batteries. Do not short or bridge the battery terminals with any object. Tripp Lite offers a
complete line of UPS System Replacement Battery Cartridges (R.B.C.). Visit Tripp Lite
on the Web at www.tripplite.com/support/battery/index.cfm to locate the specific 
replacement battery for your UPS.

• The UPS batteries are recyclable. Refer to local codes for disposal requirements, or in the

USA only call 1-800-SAV-LEAD or 1-800-8-BATTERY (1-800-8-228-8379) or visit
www.rbrc.com for recycling information. Do not dispose of the batteries in a fire. 

• Do not attempt to add external batteries.

SAVE THESE  INSTRUCTIONS

This manual contains instructions and warnings that should be followed during the 
installation, operation and storage of all Tripp Lite UPS Systems. Failure to heed these
warnings will void your warranty.

Содержание Line-Interactive UPS System SMART750USB

Страница 1: ...port 773 869 1234 www tripplite com Important Safety Instructions 2 Quick Installation 3 Basic Operation 4 Storage Service 7 Specifications 8 SMART750USB 120V Input Line Interactive UPS System Copyrig...

Страница 2: ...r warranty will be voided if anything other than Tripp Lite surge suppressors are used to connect your UPS to an outlet If the UPS receives power from a motor powered AC generator the generator must p...

Страница 3: ...ry index cfm to locate the specific Tripp Lite replacement battery for your UPS Basic Operation continued 4 ON OFF Button To turn the UPS ON if utility power is present the UPS will turn ON automatica...

Страница 4: ...batteries discharged for an extended period of time they will suffer a permanent loss of capacity Storage Service All Indicator Light descriptions apply when the UPS is plugged into an AC outlet and t...

Страница 5: ...ted provide this information to your telephone company 2 If your Fax Modem Protector causes harm to the telephone network the telephone company may temporarily discontinue your service If possible the...

Страница 6: ...sitivo que no sea un supresor de sobretensiones Tripp Lite para conectar su UPS a una toma de corriente Si el UPS recibe energ a de un generador de CA accionado por motor el generador debe proporciona...

Страница 7: ...ipp Lite espec fica para su UPS Operaci n b sica contin a 12 Bot n ON OFF Encendido Apagado Para encender el UPS si hay energ a de la red el UPS se encender en forma autom tica Si no hay energ a de la...

Страница 8: ...eraci n b sica contin a Todas las descripciones de luces indicadoras se aplican cuando el UPS est conectado a una salida de CA y encendido LED LINE POWER Energ a de l nea Este LED verde se enciende co...

Страница 9: ...por adelantado a fin de usted que tenga la oportunidad de mantener un servicio sin interrupciones 4 Si experimenta problemas con este protector de fax m dem p ngase en contacto con el Soporte al clie...

Страница 10: ...ipplite com Consignes de s curit importantes 20 Installation rapide 21 Fonctionnement basique 22 Stockage Service 26 Sp cifications 27 SMART750USB Syst mes d alimentation continue sans coupure de seco...

Страница 11: ...nnecter votre syst me d alimentation continue sans coupure une sortie Si le syst me d alimentation continue sans coupure re oit une alimentation d un g n rateur CA moteur le g n rateur doit assurer un...

Страница 12: ...imentation continue sans coupure Suite de Fonctionnement basique 22 Bouton ON OFF Pour allumer le syst me d alimentation continue sans coupure si l alimentation de service est pr sente le syst me d al...

Страница 13: ...inuellement quand le syst me d alimentation continue sans coupure est allum et d livre votre quipement l ali mentation CA depuis une source de service La LED clignote pour vous rappeler que vous avez...

Страница 14: ...ice ininterrompu 4 Si vous rencontrez des probl mes avec ce Protecteur Fax Modem veuillez contacter l Assistance Technique Clients de Tripp Lite 1111 W 35th Street Chicago Illinois 60609 T l phone 773...

Страница 15: ...1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com 200308144 93 2176...

Отзывы: