Hardware Setup 

continued

Rackmounting

The B021-02R-17 is designed for mounting in a 1U 
rack system. The various mounting options are 

explained in the sections that follow.

2-Post Rackmounting

The B021-02R-17 can also be mounted in a 2-post rack using the optional 2-Post Rackmount Kit (Model: 
B019-000). The mounting hardware allows for the console to be opened with the drawer in any position. The kit 
provides added stability and prevents the console frame from twisting. See the B019-000 Owner's Manual for 

detailed 
mounting instructions.

Installation

1

   

Turn off the power to all devices that are being connected. You must unplug the power cord of any computer 

that has the Keyboard Power On function.

2

   

Connect the Yellow HD18 connector on the included KVM cable kit to the computer port on the back of the 

unit.

3

   

Connect the Blue HD15 connector on the included KVM cable kit to the HD15 port on your computer or KVM.

4

   

Connect the USB connector or PS/2 connectors on the included KVM cable kit to a USB port or the PS/2 

ports on your computer or KVM.

5

     

If you are installing an external console, connect your external VGA monitor and USB or PS/2 keyboard and 
mouse to the external console ports on the unit.

6

   

Connect the included power cord from the console to a Tripp Lite Surge Suppressor, Power Distribution Unit 
(PDU) or Uninterruptible Power Supply (UPS).

7

   Turn on the power to the console.

8

     

Turn on the power to the connected computer or KVM.

2

   

Take the console and gently slide it into the two 

rear-mounted brackets in the rack and secure the 
console in place by inserting user-supplied screws. 

Standard 4-Post Rackmounting

The standard rackmounting brackets that come 

attached to the B021-02R-17 allow the unit to be 
installed in standard 1U racks by a single individual. 

1

   

Slide out the rear mounting brackets from the 

console and mount both brackets (separate from 

the console) to the inside rear of a standard 1U 
rack system using user-supplied screws. 

Содержание B021-02R-17

Страница 1: ...r i p p l i t e c o m w a r r a n t y Owner s Manual 17 in USB PS2 Dual Rail Console Model B021 02R 17 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2010 Tripp Lite All...

Страница 2: ...USB or PS 2 connectors Compatible with all operating systems and most KVMs with a VGA and USB or PS 2 ports Back panel of the unit includes external VGA PS 2 x2 and USB x2 ports for connecting an exte...

Страница 3: ...en fully extended the keyboard module locks into place Pulling the release catches on both sides of the keyboard panel will allow you to slide the module back into the rack 7 LCD Release Catch When fu...

Страница 4: ...you to slide the module back into the rack 2 Reset Button Pressing the reset button will perform a system reset Note The reset button is semi recessed and should be pushed with a thin object such as a...

Страница 5: ...d be in the Normal postion When recovering from a failed firmware upgrade this switch should be in the Recover position See Firmware Upgrade Recovery on page 13 for details Rear View 1 C14 Power Socke...

Страница 6: ...consult your dealer or local power company To prevent damage to your installation ensure that all devices are properly grounded The device is equipped with a 3 wire grounding type plug This is a safet...

Страница 7: ...the rack rests on the floor Install front and side stabilizers on a single rack or front stabilizers for joined multiple racks before working on the rack Always load the rack from the bottom up and l...

Страница 8: ...to the HD15 port on your computer or KVM 4 Connect the USB connector or PS 2 connectors on the included KVM cable kit to a USB port or the PS 2 ports on your computer or KVM 5 If you are installing an...

Страница 9: ...odule Note The maximum load bearing capacity of the keyboard module is 66 lbs 30 kg Do not lean your body weight on the keyboard module or place heavy objects on it Opening the Console Modules 1 The c...

Страница 10: ...d and push the keyboard module into the rack 2 You can let go of the release catches once the unit has been pushed forward and slide the unit the rest of the way into the rack 3 To close the LCD modul...

Страница 11: ...12 for details Ctrl Alt Shift l Enter Enables access to the connected computer KVM via the built in local console only Access via the external remote console is disabled Ctrl Alt Shift r Enter Enable...

Страница 12: ...en the upgrade is complete the Status Message panel will inform you that the firmware upgrade was OK At this point click Finish to complete the firmware upgrade Firmware Upgrade As firmware upgrade fi...

Страница 13: ...are upgrade cable from the RJ11 firmware upgrade port on the LCD panel of the switch to a DB9 Serial port on the computer you saved the firmware to 4 Proceed with the firmware upgrade starting with st...

Страница 14: ...B A Male x1 MiniDIN6 Male x2 via included KVM cable kit Power Jack IEC 320 C14 I P Rating 100 240V 50 60Hz 1A Power Consumption 29 6W On Off Power Switch Yes Reset Button Yes Keyboard Mouse Emulation...

Страница 15: ...amages direct indirect special or consequential to the product incurred during shipment to Tripp Lite or an authorized Tripp Lite service center is not covered under warranty Products shipped to Tripp...

Отзывы: