 2 – Important Safety Instructions 

(continued)

 

 

 

Battery Warnings 

 

 

The battery cabinet does not require routine maintenance by the user. There are no user-serviceable parts inside. Only 
qualified, knowledgeable service personnel familiar with all required precautions should open the access panels for any 
reason.

 

Keep unauthorized personnel away from batteries. 

 

The battery cabinet contains valve-regulated recombinant lead-acid (VRLA) batteries. Do not attempt to add water to these 
batteries or sample the electrolyte specific gravity. 

 

Valve-regulated recombinant lead-acid (VRLA) batteries can contain an explosive mixture of hydrogen gas. DO NOT 
SMOKE when near batteries. DO NOT cause flames or sparks near batteries. Discharge static electricity from body before 
touching batteries. DO NOT open or mutilate batteries—released electrolyte is harmful to the skin and eyes and may be 
toxic. DO NOT dispose of batteries in a fire—they may explode. 

 

Batteries present a risk of electrical shock and burns from high short-circuit current. Battery connection or replacement 
should be performed only by qualified service personnel, observing proper precautions. Use tools with insulated handles. 
Remove watches, rings or other metal objects. Wear rubber gloves and boots. Do not short or bridge the battery terminals 
with any object. Do not lay tools or metal parts on top of batteries. 

 

Replace batteries with equivalent batteries (same number and type) available from Tripp Lite. 

 

The batteries are recyclable. Refer to local codes for disposal requirements. Do not dispose of  batteries except through 
approved channels in accordance with all applicable local, state and national regulations. 

 

Fuses should be replaced by qualified service personnel only. Blown fuses must be replaced with the same number and type 
of fuses. 

 

Do not connect or disconnect batteries when the UPS system is operating from the battery supply or when the unit is not in 
bypass mode. Disconnect the charging source prior to connection or disconnecting battery terminals. 

 

If the charging source remains off for an extended period of time, it should be turned on periodically to allow the batteries to 
recharge. The charging source should be turned on and the batteries should be recharged at least one uninterrupted 24-hour 
period every 3 months. Failure to recharge the batteries periodically may cause permanent battery damage. 

 

Allow batteries to charge uninterrupted for 24 hours after installation. 

 

Do not attempt to service the integrated battery charger (included with “C” models only). Contact Tripp Lite if service is 
required. 

 
 
 
 

Note on Labeling 

 

These symbols may appear on the product label: 
 

V~

 AC 

Voltage 

V

 DC 

Voltage 

 

 

 Ground 

+

 Battery 

Positive 

-

 Battery 

Negative 

 
Refer to the product label for model numbers, voltage 
ratings and other important information. 

Содержание 3-Phase Battery Cabinet Extended-Run

Страница 1: ...Check 4 Operation and Charging 4 1 Determine Charging Voltages 4 2 Initial Charge 4 3 Operational Check 4 4 Acceptance Test Optional 5 Maintenance 5 1 Maintenance Schedule 5 2 Fuse Replacement 6 Diag...

Страница 2: ...ropriate ventilation and convection cooling of the individual batteries is provided via inch spacing between batteries Front and rear vents allow the free flow of warmer air out of the battery cabinet...

Страница 3: ...e support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recom...

Страница 4: ...h any object Do not lay tools or metal parts on top of batteries Replace batteries with equivalent batteries same number and type available from Tripp Lite The batteries are recyclable Refer to local...

Страница 5: ...Fully extend forks under load Spread forks to maximum possible width under load Lift cabinet from bottom only Wear safety shoes Confirm that load limits for freight elevators handling equipment and f...

Страница 6: ...the output load connection points Measure voltage with a digital voltmeter 2 The measured voltage should approximately match the voltage listed on the battery cabinet nameplate The battery cabinet out...

Страница 7: ...4 The top and sides of the battery cabinet include knockouts for load connection cable entry Punch out the appropriate knockout and connect the conduit or cable bushing 5 The output terminal blocks f...

Страница 8: ...attery terminals 2 Measure and record the system float current using a clamp on ammeter 3 Measure and record the float voltage of individual battery units 4 Measure and record the temperature of sever...

Страница 9: ...annual check 2 Use insulated tools to tighten all connections to the recommended torque See Section 7 2 for recommended torque values 3 Optional Measure inter battery connection resistance 5 2 Fuse Re...

Страница 10: ...s are in inches Conduit Knockouts Conduit Knockouts Breaker Mounting Plate 79 4 5 4 38 15 75 6 4 5 2 25 22 8 25 24 75 16 16 16 4 11 75 5 5 40 25 30 25 6 6 34 5 17 25 Side View Side View Front View Sid...

Страница 11: ...e All dimensions are inches 58 Front of Cabinet Front of Cabinet Breaker Mounting Plate Conduit Knockouts Conduit Knockouts 15 75 2 25 Side View Side View Side View Side View Bottom View Top View Fron...

Страница 12: ...0 VDC Breaker is UL listed and rated for 150 A 600 VDC 25 KAIC Cabinets with breakers are shipped with the breaker in the off open position Battery arrangements shown are typical but may vary dependin...

Страница 13: ...250 A 600 VDC 25 KAIC Cabinets with breakers are shipped with the breaker in the off open position Battery arrangements shown are typical but may vary depending on cabinet and battery type Shelf 1 Bo...

Страница 14: ...suitable for 120 VAC input Temperature compensation with remote battery temperature sensor Auxiliary output circuit for Charger OK indicator 6 25 MAX 0 5 12 5 13 5 Terminal Block Detail Input Voltage...

Страница 15: ...cm 2284 lb 1038 kg 271 lb ft 2 1322 kg m 2 BP348V78 4 40 25 x 30 25 x 79 inches 102 2 x 76 8 x 200 7 cm 2545 lb 1157 kg 301 lb ft 2 1474 kg m 2 BP348V103 4 40 25 x 30 25 x 79 inches 102 2 x 76 8 x 20...

Страница 16: ...rs should contact Tripp Lite support at intlservice tripplite com THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT MISUSE ABUSE OR NEGLECT SELLER MAKES NO EXPRESS WARRA...

Отзывы: