![Triplett CM400 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/triplett/cm400/cm400_user-manual_1163981012.webp)
Specifications
Note: Accuracy is given as ±(% of r counts of least significant digit) at 23
o
C /±5
,
with relative humidity less than 80%RH.
Function
Range
Resolution
Accuracy ±(% of
digits)
AC True RMS
Current
40.00A
10mA
±2.0% of rdg ± 8 digits
400.0A
100mA
±2.5% of rdg ± 8 digits
Over rang protection: Maximum input 400A;
Accuracy specified from 5% to 100% of the measuring range;
Frequency Response: 50Hz to 60Hz True RMS;
Inrush current Maximum Input: 400A; Inrush current Sensitivity: >2A.
AC True RMS
Voltage (with
VFD)
4.000V
1mV
±1.2% of rdg ± 5 digits
40.00V
10mV
400.0V
100mV
1000V
1V
±1.5% of rdg ± 5 digits
Variable frequency drive test AC voltage rang: 100V-600V.
AC voltage bandwidth:50 to 1000Hz(Sine); 50/60(All wave).
Accuracy specified from 5% to 100% of the measuring range.
Maximum Input: 1000V ac rms. PEAK Maximum Input: 1000V.
DC Voltage
4.000V
1mV
±1.0% of rdg ± 3 digits
40.00V
10mV
400.0V
100mV
1000V
1V
±1.2% of rdg ± 3 digits
Maximum Input: 1000V dc
Resistance
400.0Ω
0.1Ω
±1% of rdg ± 4 digits
4.000kΩ
1Ω
±1.5% of rdg ± 2 digits
40.00kΩ
10Ω
400.0kΩ
100Ω
4.000MΩ 1kΩ
±2.0% of rdg ± 5 digits
40.00MΩ 10kΩ
±3% of rdg ± 8 digits
Input Protection: 300V dc or 300V ac rms.