background image

Herrmidicool

I n s t a l l a t i o n ,   O p e r a t i o n   &   M a i n t e n a n c e   M a n u a l

9

www.trioniaq.com

Brass Nozzle Consists of:

SS Nozzle Consists of:

Part #

Description

Part #

Description

253205-001

Nozzle Body

253205-002

Nozzle Body

253209-001

Bonnet

253209-002

Bonnet

AH-941-1-”X”

Air Nozzle

AH-941-2-”X”

Air Nozzle

AH-942-1(R)

Water Nozzle

AH-942-2(R)

Water Nozzle

253206-001

Cap

253206-002

Cap

253207-001

Spring Tension Nut

253207-002

Spring Tension Nut

253208-001

Spring Nut

253208-002

Spring Nut

AH-12(R)

Valve Stem w/ Needle

AH-12(R)-SS

Valve Stem w/ Needle

AH-19A

Air Port

AH-19ASS

Air Port

AH-18A

Union Tail Piece

AH-18ASS

Union Tail Piece

AH-20

Union Nut

AH-20SS

Union Nut

AH-1RK (Note 1)

Rebuild Kit

AH-1RK

Rebuild Kit

“X” Denotes nozzle rating in pounds/hour (6, 8, 10, 12 or 15 lb/hr).
Notes:

1.  AH-1RK Kit includes: AH-10, AH-122 “O” Ring, AH-14 Air Nozzle Gasket, AH-15 Water Nozzle 

Gasket, AH-16 Valve Disk, AH-21 Strainer Screen, AH-23 Diaphragm Washer, AH-8 Spring, FV-17-

1 Union Washer

2.  Always specify nozzle rating in lbs/hr on any nozzle parts order.

3.  The notation for (R) is used when capacity of head is 6 or 8 lbs/hr.

XVI. NOZZLE DIAGRAM

Содержание HERRMIDIFIER Herrmidicool

Страница 1: ...T R I O N w w w t r i o n i a q c o m Herrmidicool Installation Operation Maintenance READ SAVE THESE INSTRUCTIONS...

Страница 2: ...ion 4 II Operational Characteristics 4 III Mounting 4 IV Plumbing 4 V Controls 5 VI Control Board Operation 5 VII Start up Checklist 6 VIII Start up 7 IX Atomizing Head Operation 7 X Pressure Settings...

Страница 3: ...OROUGHLY BEFORE INSTALLING OR SERVICING THE UNIT DANGER OF BURNS THE HUMIDIFIER CONTAINS HIGH TEMPERATURE COMPONENTS AND DELIVERS STEAM AT 100 C 212 F ATTENTION READ THIS MANUAL FACTORY INSTALLED OPTI...

Страница 4: ...ata prior to selecting equipment NOTE If units are mounted in outdoor enclosures conditions inside enclosure must be maintained as listed above III MOUNTING The Herrmidicool system consists of two bas...

Страница 5: ...as inside of comers Air proving devices should be mounted so that they sense airflow or the absence of it Wire the device so that it closes when airflow is present and will open when there is no airfl...

Страница 6: ...GING SOME OF THESE SETTINGS MAY RENDER THE FACTORY WARRANTY VOID When touching SETUP or MODULE STATUS the administrator will be prompted for a password Enter 2222 to log in to the controller Network s...

Страница 7: ...settings at any other time The instructions below assume that the atomizing heads are installed at the same elevation as the water control section Adjustment from this standard must be made to compens...

Страница 8: ...reign matter may be restricting water flow in the water nozzle AH 942 Turn off the air and water valves at the head Remove the atomizer nozzle and water nozzle Blow water nozzle with air Do not use wi...

Страница 9: ...Spring Nut 253208 002 Spring Nut AH 12 R Valve Stem w Needle AH 12 R SS Valve Stem w Needle AH 19A Air Port AH 19ASS Air Port AH 18A Union Tail Piece AH 18ASS Union Tail Piece AH 20 Union Nut AH 20SS...

Страница 10: ...i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 10 www trioniaq com XVI WIRING DIAGRAM WARNING Absolutely no other components may be mounted inside or electrically tapped into the humidifie...

Страница 11: ...Herrmidicool I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 11 www trioniaq com THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 12: ...2018 TRION All Rights Reserved TRION 101 McNeill Rd Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioniaq com customerservice trioniaq com Form No 269604 001 Rev 06 18...

Отзывы: