1. Warranty

Humidifier 5-Year Limited Warranty

This  limited  warranty  covers  Trion  Residential  Type  Humidifiers, 

excluding duct work, wiring and installation. Trion warrants that all new 

Trion  humidifiers  are  free  from  defects  in  material  and  workmanship 

under normal, non-commercial use and service. Trion will remedy any 

covered defects if they appear within 60 months from the date of original 

installation & subject to the terms and conditions of this Limited 5-Year 
Warranty stated below:

1. 

THIS LIMITED 5-YEAR WARRANTY is granted by Trion Customer 

Service, 101 McNeill Road, Sanford, NC 27330.

2.  This warranty shall extend only to any non-commercial owner who 

has purchased the residential humidifier other than for purposes 

of resale.

3. 

All  components  are  covered  by  this  limited  warranty  except 

expendable  items,  such  as  evaporative  pads,  media  filter  pads 

and nozzles.

4. 

If, within the warranty period, any Trion residential humidifier unit or 

component requires service it must be performed by a competent 

heating and/or air conditioning contractor (preferably the installing 

contractor). Trion will not pay shipping charges, or labor charges 

to remove or replace such defective parts or components. If the 

part or component is found by inspection to contain such defective 

material and workmanship it will be either repaired or exchanged 

free of charge at Trion’s option, and returned freight collect.

5. 

In order to obtain the benefits of this limited 5-year warranty, the 

owner must notify the dealer or distributor of any defect within 30 

days of its discovery. If after reasonable time you have not received 

an  adequate  response  from  the  dealer  or  distributor,  notify  in 

writing to Trion Customer Service 101 McNeill Road, Sanford, NC 

27330, or call 1-800-884-0002 or email customerservice@trioniaq.

com Humidifiers which have been installed or become part of real 

estate cannot be returned. Trion will receive, freight prepaid, only 

removable parts or components of such defective humidifiers.

6.  This limited warranty does not apply to any part or component 

that  is  damaged  in  transit  or  in  handling,  has  been  subject  to 

misuse,  neglect  or  accident;  has  not  been  installed,  operated 

and serviced according to Trion’s instructions; has been operated 

beyond the factory rated capacity; or altered in any such way that 

its performance is affected. There is no warranty due to neglect, 

alteration  or  ordinary  wear  and  tear.  Trion’s  liability  is  limited  to 

replacement of defective parts or components and does not include 

the payment of the cost of labor charges to remove or replace such 

defective components or parts.

7. 

Trion  will  not  be  responsible  for  loss  of  use  of  any  product; 

loss  of  time,  inconvenience,  or  any  other  indirect,  incidental  or 

consequential damages with respect to person or property, whether 

as  a  result  of  breach  of  warranty,  neglect  or  otherwise.  SOME 

STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION 

OF  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES,  SO  THE 

LIMITATION OR EXCLUSION IN THE PRECEDING SENTENCE 

MAY NOT APPLY TO YOU. 

8. 

THIS  WARRANTY  GIVES  YOU  SPECIFIC  RIGHTS, AND  YOU 

MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE 

TO STATE.

9. 

Any  warranty  by  Trion  of  merchantability,  fitness  for  use  or  any 

other  warranty  (express,  implied  or  statutory),  representation  or 

guarantee  other  than  those  set  forth  herein,  shall  expire  at  the 

expiration date of this express limited warranty. SOME STATES 

DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED 

WARRANTY LASTS, SO THE LIMITATION IN THE PRECEDING 

SENTENCE MAY NOT APPLY TO YOU.

10.  Trion reserves the right to make changes in the design and material 

of its products without incurring any obligation to incorporate such 

changes in units completed on the effective date of such change.

2. Safety & Warnings

!

DANGER

RISK OF ELECTRIC SHOCK

Before cleaning, servicing, or parts replacement, the unit must 
be disconnected from all sources of electricity.

!

WARNING

Improper installation, adjustment, alteration, service, or main

-

tenance may cause property damage, injury, or death.  This 
appliance must be installed according to these instructions.  
Read these instructions thoroughly before installing or servic

-

ing the unit.

!

CAUTION

Read these instructions thoroughly before installing this unit.  
Check  data  label  and  verify  electrical  specifications  agree 

with those at the point of installation.

!

WARNING

Failure to install this unit in a position that is level and plumb 
may impair the unit’s ability to drain if an overflow condition 

presents itself.  Damage to personal property may also result.

!

WARNING

Installation in freezing conditions can result in unit failure. 
Damage to personal property may also result.  

!

WARNING

A drain pan should be installed under the unit and any supply 

water / drain connections to prevent damage to property in the 
event of a water leak or faulty operation.

!

CAUTION

Trion  recommends  that  this  humidifier  be  installed  by  a 

trained HVAC professional.  Do not connect the unit to the 

power source until the installation is complete.  A thorough 

checkout of the unit installation should be completed before 

operating the unit.  Failure to follow these directions may void 

the manufacturer’s original warranty.

!

WARNING

Electrical power to the furnace must be disconnected before 

proceeding. Serious injury or death may result.

Содержание ComfortBREEZE CB10

Страница 1: ...Tr i o n w w w t r i o n i a q c o m ComfortBREEZE TM CB100 CB100S Flow Through Evaporative Humidifier READ AND SAVE THESE INSTRUCTIONS...

Страница 2: ...ecifications Table 4 3 3 What s in the Box 4 4 Installation 4 4 1 Clearances 4 4 2 Mounting 4 4 3 Plumbing 6 4 4 Electrical Wiring 7 4 4 1 Wiring CB100 without water saving controls 7 4 4 2 Wiring CB1...

Страница 3: ...ts or components and does not include the payment of the cost of labor charges to remove or replace such defective components or parts 7 Trion will not be responsible for loss of use of any product lo...

Страница 4: ...ed range of 30 40 relative humidity assures automatic humidity control during the heating season A lower setting may be necessary to prevent condensation on windows An electronic humidistat is supplie...

Страница 5: ...ded humidistat range is 30 40 relative humidity If condensation occurs on windows the humidistat setting must be lowered to prevent condensation damage DO NOT install the humidifier where freezing tem...

Страница 6: ...debris that may have accumulated in the line during the installation process Once this is complete close the saddle valve 3 Attach the line to the humidifier by simply pushing the line into the push t...

Страница 7: ...SOLENOID VALVE BLK WHT GRN MOTOR DUCT THERMISTOR UNIT THERMISTOR MANUAL HUMIDISTAT SWITCH AIR PROVING HUMIDISTAT ELECTRONIC OR TERMINALS SEE FROM SYSTEM WIRING NOTES LINE CORD 120 VAC TERMINALS SEE T...

Страница 8: ...A solid red LED Service indicator light may light up This will tell you that it is time to service your humidifier Please refer the following procedure DIP 4 Furnace Runs Fan Humidifier Runs Fan In mo...

Страница 9: ...ng from the motor to the circuit board if equipped or disconnect the 3 wire connector 7 Lift the entire dome from the base of the unit by pulling the bottom of the dome away from the base and then lif...

Страница 10: ...vaporator pad The unit will continue to operate and the LED may be cleared by pressing the reset button on the control board 6 3 Motor Replacement 1 Follow steps 1 7 in the pad replacement section in...

Страница 11: ...se is blown Replace circuit board Motor will not operate turn Motor internal thermal protective device is open Remove power and allow motor to cool Restart unit and ensure proper operation If motor wi...

Страница 12: ...ComfortBREEZE TM Model CB100 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 12 www trioniaq com 11 10 3 13 22 12 Figure 17...

Страница 13: ...ComfortBREEZE TM Model CB100 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 13 www trioniaq com 29 7 8 14 6 21 16 15 1 16 18 17 20 20 4 Figure 18...

Страница 14: ...ComfortBREEZE TM Model CB100 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 14 www trioniaq com 29 7 9 14 6 25 19 16 15 1 16 17 2 Figure 19...

Страница 15: ...OUD 1 1 11 266371 001 COMFORTBREEZE MOTOR MAIN DOME 1 1 12 265462 001 COMFORTBREEZE MOTOR CAP 1 1 13 265463 001 COMFORTBREEZE DOME ACCESS DOOR 1 1 14 265470 001 PAD EVAPORATOR 1 1 15 265471 001P PAINT...

Страница 16: ...Trion 101 McNeill Rd Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioniaq com customerservice trioniaq com Trion 2015 All Rights Reserved Form No 265817 002 Rev 02 15...

Отзывы: