ELIMINATOR OWNER’S MANUAL
Page 6
Step 7.
Remove the six screws to free the venturi ring and the motor/blower assembly
from the lid assembly. (see Figure 6).
Step 8.
Using a 5/32” (0.42 cm) Allen wrench, remove the blower wheel from the motor
shaft. Remove six #10 hex head bolts to remove the motor from the venturi ring.
Step 9.
Replace with the new motor and reassemble by reversing the above steps. Set
the spacing between the venturi ring and the blower wheel at 0.06” (0.15 cm) clearance.