extremely dry nature, it can be blown off the cells
with a pressure hose or by gently tapping the end
plate of the cell.
4. Remove the mechanical pre-filter. Remove
collected dust or lint by vacuuming or brushing.
Wash with warm, soapy water.
5. Rinse all components thoroughly in warm, clear
water and allow to drip dry completely.
6. Replace pre-filters and ionizer/collector cells.
ENSURE the airflow arrows point in the direction of
airflow (towards the blower).
7. Close the access door; reconnect power to the unit.
8. Turn control switch to “ON”. If arcing occurs or the
indicating light flickers, the components may still be
damp. Turn the unit OFF and allow the cells to dry
completely.
Inspections
The motors and blowers on Trion T1300 and T2600 air
cleaners have sealed ball bearings and never need
lubricating.
Belt tension should be checked periodically. When a
moderate force is applied to the belt midway between
the pulleys, the belt should deflect approximately ½ “
(13 mm).
CAUTION
Having too much tension on the belts will shorten
the belt life and place undue stress on the motor
and blower bearings.
V. REPLACEMENT PARTS ORDERING
INFORMATION
The following pages contain exploded views and Bills of
Material for the Trion T Series Air Cleaners. Use these
pages to determine the part numbers of the items
needed. To order parts contact your local Trion
representative and provide the following information:
a. Unit Model number – located on the data label near
the junction box.
b. Part Number and description – from exploded
views.
VI. WARRANTY
All Trion Electronic Air Cleaners are warranted for 3
Year Limited Warranty on units and 1 Year Limited
Warranty on replacement parts. Labor is NOT included.
Do not return defective parts without permission from
the factory and receiving a material return acceptance
number.
VII. TROUBLESHOOTING GUIDE
T1001 / T2002
Problems and Possible Causes:
1. Indicating Light Out
a. Unit not plugged in
b. Control switch “Off”
c. Cell access panel not fully closed
d. Broken cell insulator
e. Extremely dirty cells
f.
Service panel not secured in place
2. Excessive arcing noise after washing
a. Collector elements still wet – Allow more drying
time
b. See “Continuous arcing noise” below
3. Continuous arcing noise and flickering indicating
light
a. Extremely dirty collector plates
b. Bent collector plates
c. Large piece of material lodged between cell
plates
4. Contaminant
Bypass
a. Velocity of airflow is too high through unit
b. Collector plates not grounded
c. Collector cell not making solid connection to
access door and high voltage contact.
IF PROBLEM CANNOT BE DETERMINED OR
CORRECTED - CONTACT YOUR LOCAL TRION
REPRESENTATIVE OR CALL TRION CUSTOMER
SERVICE AT 1-800-884-0002 FOR ASSISTANCE.
T1300 / T2600 Troubleshooting Guide
The troubleshooting chart, shown on the next page, will
enable the user to pinpoint the cause of most problems.
Refer to the Ordering Information for replacement parts.
Before performing any troubleshooting, ensure the
correct input line voltage is present.
WARNING
Factory designed access to all electrically charged
high voltage components contain electrical
interlocks for the safety of operating personnel.
Always unplug the unit while performing service
within the cabinet.
7
Содержание Air Boss T1001 Module
Страница 8: ...9 ...
Страница 9: ...10 ...
Страница 10: ...11 ...
Страница 11: ...12 ...
Страница 12: ...13 ...
Страница 13: ...14 ...
Страница 14: ...Blower Motor Assembly FIG 6 15 ...
Страница 15: ...16 ...
Страница 16: ...17 ...
Страница 17: ...18 ...
Страница 18: ...19 ...
Страница 19: ...20 ...
Страница 20: ...21 ...
Страница 21: ...22 ...