II. PREPARATION FOR INSTALLATION

 

 

This manual should be carefully read before starting the 
preparation and installation of the air cleaner. 
 
The installation should conform to all local ordinances 
associated with building codes and electrical codes 
required for the unit. Authorities having jurisdiction 
should be consulted before installation is made. If there 
are no local codes, the installation should conform to 
the National Electrical Code. 
 

SAFETY NOTE: 

Factory designed access to all electrically charged 
high voltage components contain electrical 
interlocks for the safety of operating personnel. Any 
additional access that may be provided in the 
system, where there is access to high voltage, must 
be equipped with such interlocks. Interlocks are 
readily available from the factory. 

 
The 575V, 3 Phase unit does not have internal motor 
overload protection. The installer must provide overload 
protection in accordance with National Electrical Code, 
Canadian Electrical Code, Part 1 or other applicable 
electrical codes. 
 
For maximum air cleaning efficiency, your air cleaner 
should be located as specified by your Trion 
representative. 
 
The unit can be either wall-mounted or chain-hung. 
Trion can supply eyebolts. 
 
 
 

NEW UNIT INSPECTION 

 

Immediately, upon receiving the unit, carefully examine 
the package for damage during transit. If the unit is 
damaged, contact the last carrier for claim filing and 
contact your Trion representative. 
 
While unpacking the unit, look for concealed shipping 
damage. If there is damage, it should be reported to the 
last carrier for claim filing. 
 

OPERATION 

 

What is your Electronic Air Cleaner? 

Your air cleaner is a high efficiency contaminant 
collector designed to remove up to 95% of the dust, 
smoke, liquid aerosol and other pollutants from the air 
passing through it. 
 

HOW IT OPERATES 

 
Polluted air is drawn into the unit by the belt driven 
blower on a T1300 or T2600 unit. The T1001 and T2002 
units require an external air handler to move the air. 

After passing through a pre-filter, the particles in the air 
are given an electrical charge supplied by the power 
supply. As the particles enter the collector cells, these 
charged particles are attracted to and collected on 
grounded collecting plates. 
 
 

 

Typical Electronic Cell Operation 

 
 

UNIT OPERATION 

 

 

Control Switch (A):

 The control switch is located on 

the cell access door. It controls the operation of the 
power pack (and the belt driven blower on the T1300 
and T2600). The control switch should be in the “OFF” 
position when the cell access door is open for 
maintenance of the unit. 
 

Indicating Light (B):

 The light located adjacent to the 

control switch is an indicator of the performance of your 
electronic air cleaner. When the control switch is “ON”, 
the blower should operate on the T1300 and T2600, 
and the indicator light should glow. If the light does not 
glow or if it continually flickers and is accompanied with 
a continual snapping or arcing noise, the air cleaner 
requires attention and may need to be cleaned. 
 

Cell Access Latches ( C ):

 The cell access latches are 

located on the door near the intake end of the unit. To 
open the cell access door, lift and turn the latches 
counter clockwise. 
 

Arcing (snapping or cracking noise):

 An occasional 

arcing noise may be emitted from the air cleaner. This is 
a normal occurrence caused by exceptionally large 
pieces of dirt, etc., entering the collecting elements. In 
addition, an arcing noise accompanied by a flickering of 
the indicating light may be noticed after washing the 
cells. Should this occur, allow more drying time. Also, 

Содержание Air Boss T1001 Module

Страница 1: ... Module T2002 Module T1300 T2600 INSTALLATION OPERATION SERVICE Electrostatic Precipitators for Commercial Industrial Applications 101 McNeill Road Sanford NC 27330 919 775 2201 Fax 919 777 6399 800 884 0002 www trioninc com T NO 149869 001 MANUAL PAR June 2004 4 ...

Страница 2: ...s 4 Unit Operation 4 Ducting Application 5 Liquid Aerosol Installation 5 Electrical Installation 6 Cleaning 6 Inspections 7 VI W T1001 T2002 7 T1300 T2600 7 Troubleshooting Diagram 8 Figure 1 T1300 Unit 9 Figure 2 T2600 Unit 10 Figure 3 T1001 Unit 11 Figure 4 T2002 Unit 12 Figure 5 Enclosure Assembly 13 Figure 6 Blower Assembly 14 Figure 7 Blower Assembly Bill of Material 15 Figure 8 Ionizer Colle...

Страница 3: ...1300A 230V 60 HZ 1 PH 3 4 5 6 T1300B 230V 60 HZ 3 PH 1 3 6 T1300C 460V 60 HZ 3 PH 1 1 8 T1300D 575V 60 HZ 3 PH 1 1 6 T1300E 230V 50 HZ 1 PH 3 4 5 9 T1300N 208V 60 HZ 3 PH 1 3 6 T2600 120V 60 HZ 1 PH 3 4 11 3 T2600A 230V 60 HZ 1 PH 3 4 5 7 T2600B 230V 60 HZ 3 PH 1 3 7 T2600B 230V 60 HZ 3 PH 2 6 5 T2600C 460V 60 HZ 3 PH 1 1 9 T2600C 460V 60 HZ 3 PH 2 3 3 T2600D 575V 60 HZ 3 PH 1 1 7 T2600E 230V 50 H...

Страница 4: ...ollector designed to remove up to 95 of the dust smoke liquid aerosol and other pollutants from the air passing through it HOW IT OPERATES Polluted air is drawn into the unit by the belt driven blower on a T1300 or T2600 unit The T1001 and T2002 units require an external air handler to move the air After passing through a pre filter the particles in the air are given an electrical charge supplied ...

Страница 5: ...READ THOROUGHLY 1 Carefully unpack unit from shipping crate or carton and examine for damage in shipment 2 Remove ionizer collector cell s pre filters and after filters 3 Attach 500 pound 227 kg test chain to the ceiling joist using a Wood joist 3 8 m10 eye bolts b Metal joist wrap chain around joist at least twice and secure with 500 pound 227 kg test connecting link 4 Chain should be cut to allo...

Страница 6: ...personnel WARNING RISK OF ELECTRIC SHOCK These serving instructions are for use by qualified personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so SAFETY NOTE Factory designed access to all electrically charged high voltage components contain electrical interlocks for the safety of ...

Страница 7: ...xploded views VI WARRANTY All Trion Electronic Air Cleaners are warranted for 3 Year Limited Warranty on units and 1 Year Limited Warranty on replacement parts Labor is NOT included Do not return defective parts without permission from the factory and receiving a material return acceptance number VII TROUBLESHOOTING GUIDE T1001 T2002 Problems and Possible Causes 1 Indicating Light Out a Unit not p...

Страница 8: ...9 ...

Страница 9: ...10 ...

Страница 10: ...11 ...

Страница 11: ...12 ...

Страница 12: ...13 ...

Страница 13: ...14 ...

Страница 14: ...Blower Motor Assembly FIG 6 15 ...

Страница 15: ...16 ...

Страница 16: ...17 ...

Страница 17: ...18 ...

Страница 18: ...19 ...

Страница 19: ...20 ...

Страница 20: ...21 ...

Страница 21: ...22 ...

Страница 22: ... Boscstr 60 No 728 Fuzhou Road D 50171 Kerpen Rm 3002 3005 Germany Raffles City Office Tower Tel 49 0 2237 922 103 Shanghai P R China 200001 Fax 49 0 2237 922 104 Tel 86 21 63403232 Email info trion deutschland de Fax 86 21 63403867 Fedders International Fedders International Inc Air Conditioning 128 Joo Seng Road A 30 Chintels House 05 01 Kalish Colony DP Computers Building New Delhi Singapore 36...

Отзывы: