TRION  

Part Number

Weight

(lbs.)

Inlet  

Connector

Outlet  

Connector

Part Number 

Flame Arrestor

Power Supply  

120          240 

VAC        VAC

439057-001

-029

141

2” Flange

_

322792-001

0

1

-002

-030

145

3” Flange

_

322792-002

1

0

0

1

-003

-031

150

4” Flange

_

322791-002

1

0

0

1

-008

-036

147

2” Flange

2” Flange

322792-001

1

0

0

1

-009

-037

155

3” Flange

3” Flange

322792-002

1

0

0

1

-010

-038

165

4” Flange

4” Flange

322791-002

1

0

0

1

-015

-043

138

2” Pipe

_

322792-001

1

0

0

1

-016

-044

141

3” Pipe

_

322792-002

1

0

0

1

-017

-045

143

4” Pipe

_

322791-002

1

0

0

1

-022

-050

141

2” Pipe

2” Pipe

322792-001

1

0

0

1

-023

-051

147

3” Pipe

3” Pipe

322792-002

1

0

0

1

-024

-052

151

4” Pipe

4” Pipe

322791-002

1

0

0

1

-061

-062

159

6” Flange

_

322791-001

1

0

0

1

-060

-059

183

6” Flange

6” Flange

322791-001

1

0

0

1

150 CFM PARTS

NOTES:

1.  The part number for the Ionizer Cell for all units on this page is 422728-011. Only one required.

2.  The part number for the Collector Cell for all units on this page is 422729-003. Only one required.

3.  Flame arrestor not supplied but required in pipe inlet applications.

VII.  OUTLINE DRAWINGS 

OUTLINE DRAWINGS (SUBSEQUENT PAGES)

The “weatherproof power pack” and “weatherproof junction box” are designed to offer protection to IP-54.  The junction 

box for 220-240 VAC models is furnished with a terminal block for connection of field installed supply power wiring.  

The terminal block is earthed to the junction box through the earth terminal (PE) and includes a 1.2 Amp fuse for the 

line connection (L).  A third unfused terminal is included for the neutral (N) supply wire.  A strain relief connector for 

connecting a supply cable to the junction box, suitable for cable diameters of 4.8 to 7.9 mm, is furnished.  It is packaged 

with the junction box.

Содержание Air Boss 38 Series

Страница 1: ...T R I O N w w w t r i o n i a q c o m Air Boss Model 38 Series Industrial Mist Precipitator READ AND SAVE THESE INSTRUCTIONS Installation Operation Maintenance Parts Manual...

Страница 2: ...4 III Operation 4 IV Maintenance 5 V Troubleshooting 5 VI Recommended Spare Parts 6 VII Outline Drawings 150 CFM Parts 7 150 CFM Outline Drawing with Inlet Flange or Pipe 424396 8 150 CFM Outline Draw...

Страница 3: ...ted on the discharge side of the collector section provides protection especially on units installed with an open discharge The baffle also slides into the cabinet like a drawer All three of these com...

Страница 4: ...l Place in safe location being careful not to deform the high voltage spring contacts in the under side 3 Remove flame arrestor ionizer collector and outlet baffle and place them aside with access pan...

Страница 5: ...checked Access to the power supply is gained by removing the primary power cable and power pack cover V TROUBLESHOOTING NOTE EXERCISE THE NORMAL PRECAUTIONS WHEN WORKING WITH HIGH VOLTAGE A PILOT LIGH...

Страница 6: ...ionizer current should be between 0 5 and 1 5 mA 5 Loose or faulty high voltage connection between power supply and ionizer collector elements Check secondary wiring from power supply to high voltage...

Страница 7: ...0 0 1 060 059 183 6 Flange 6 Flange 322791 001 1 0 0 1 150 CFM PARTS NOTES 1 The part number for the Ionizer Cell for all units on this page is 422728 011 Only one required 2 The part number for the C...

Страница 8: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 8 www trioniaq com 150 CFM Outline Drawing with Inlet Flange or Pipe 424396...

Страница 9: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 9 www trioniaq com 150 CFM Outline Drawing with Inlet Outlet Flange or Pipe 424397...

Страница 10: ...8 046 153 2 Pipe _ 322792 001 1 0 0 1 019 047 156 3 Pipe _ 322792 002 1 0 0 1 020 048 158 4 Pipe _ 322791 002 1 0 0 1 021 049 164 6 Pipe _ 322790 001 1 0 0 1 025 053 156 2 Pipe 2 Pipe 322792 001 1 0 0...

Страница 11: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 11 www trioniaq com 300 CFM Outline Drawing with Inlet Flange or Pipe 424399...

Страница 12: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 12 www trioniaq com 300 CFM Outline Drawing with Inlet Outlet Flange or Pipe 424398...

Страница 13: ...tor Part Number Flame Arrestor Power Supply 120 240 VAC VAC 439057 063 355 8 Flange 8 Flange 322791 003 1 0 439057 064 355 8 Flange 8 Flange 322791 003 0 1 600 CFM PARTS NOTE 1 The part number for the...

Страница 14: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 14 www trioniaq com 600 CFM Outline Drawing 429436...

Страница 15: ...ONIZER BLK WHT IONIZER BLK GRN WHT 120V 50 60 HZ 1 LINE GROUND NEUTRAL BLK RED LED 120VAC CATHODE ANODE NEUT GRD POWER SUPPLY RED BLACK BLK WHT BOX MOUNTING RECEPTACLE PRIMARY LEAD AND PLUG ASSY ENCLO...

Страница 16: ...nd 300 CFM 268678 003 Primary Plug and Receptacle Assembly 240 VAC Input Voltage 150 and 300 CFM 1 268678 002 Primary Plug and Receptacle Assembly 120 VAC Input Voltage 600 CFM 268678 004 Primary Plug...

Страница 17: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 17 www trioniaq com V DIAGRAM 3 6 5 1 4 2...

Страница 18: ...Form No 61 0184 Rev 10 16 TRION 2016 All Rights Reserved TRION 101 McNeill Rd Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioniaq com customerservice trioniaq com...

Отзывы: