background image

Model 38 Series

I n s t a l l a t i o n ,   O p e r a t i o n ,   &   M a i n t e n a n c e   M a n u a l

10

www.trioniaq.com

TRION  

Part Number

Weight

(lbs.)

Inlet  

Connector

Outlet  

Connector

Part Number 

Flame Arrestor

Power Supply  

120          240 

VAC         VAC

439057-004

-032

156

2” Flange

_

322792-001

0

1

-005

-033

160

3” Flange

_

322792-002

1

0

0

1

-006

-034

165

4” Flange

_

322791-002

1

0

0

1

-007

-035

174

6” Flange

_

322791-001

1

0

0

1

-011

-039

162

2” Flange

2” Flange

322792-001

1

0

0

1

-012

-040

170

3” Flange

3” Flange

322792-002

1

0

0

1

-013

-041

180

4” Flange

4” Flange

322791-002

1

0

0

1

-014

-042

198

6” Flange

6” Flange

322791-001

1

0

0

1

-018

-046

153

2” Pipe

_

322792-001

1

0

0

1

-019

-047

156

3” Pipe

_

322792-002

1

0

0

1

-020

-048

158

4” Pipe

_

322791-002

1

0

0

1

-021

-049

164

6” Pipe

_

322790-001

1

0

0

1

-025

-053

156

2” Pipe

2” Pipe

322792-001

1

0

0

1

-026

-054

162

3” Pipe

3” Pipe

322792-002

1

0

0

1

-027

-055

168

4” Pipe

4” Pipe

322791-002

1

0

0

1

-028

-056

178

6” Pipe

6” Pipe

322791-001

1

0

0

1

-057

179

4” Flange

6” Flange

322791-001

1

0

    -065*

162

3” Pipe

3” Pipe

322792-002

1

0

300 CFM PARTS

NOTE:

1.  The part number for the Ionizer Cell for all units on this page is 422728-012. Only one required.

2.  The part number for the Collector Cell for all units on this page is 422729-002. Only one required.

3.  Flame arrestor not supplied but required on pipe inlet applications.

* Stainless Steel Ionizer & Collector Cell 

•  Ionizer Part No. 431318-001

•  Collector Cell Part No. 431319-001

Содержание Air Boss 38 Series

Страница 1: ...T R I O N w w w t r i o n i a q c o m Air Boss Model 38 Series Industrial Mist Precipitator READ AND SAVE THESE INSTRUCTIONS Installation Operation Maintenance Parts Manual...

Страница 2: ...4 III Operation 4 IV Maintenance 5 V Troubleshooting 5 VI Recommended Spare Parts 6 VII Outline Drawings 150 CFM Parts 7 150 CFM Outline Drawing with Inlet Flange or Pipe 424396 8 150 CFM Outline Draw...

Страница 3: ...ted on the discharge side of the collector section provides protection especially on units installed with an open discharge The baffle also slides into the cabinet like a drawer All three of these com...

Страница 4: ...l Place in safe location being careful not to deform the high voltage spring contacts in the under side 3 Remove flame arrestor ionizer collector and outlet baffle and place them aside with access pan...

Страница 5: ...checked Access to the power supply is gained by removing the primary power cable and power pack cover V TROUBLESHOOTING NOTE EXERCISE THE NORMAL PRECAUTIONS WHEN WORKING WITH HIGH VOLTAGE A PILOT LIGH...

Страница 6: ...ionizer current should be between 0 5 and 1 5 mA 5 Loose or faulty high voltage connection between power supply and ionizer collector elements Check secondary wiring from power supply to high voltage...

Страница 7: ...0 0 1 060 059 183 6 Flange 6 Flange 322791 001 1 0 0 1 150 CFM PARTS NOTES 1 The part number for the Ionizer Cell for all units on this page is 422728 011 Only one required 2 The part number for the C...

Страница 8: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 8 www trioniaq com 150 CFM Outline Drawing with Inlet Flange or Pipe 424396...

Страница 9: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 9 www trioniaq com 150 CFM Outline Drawing with Inlet Outlet Flange or Pipe 424397...

Страница 10: ...8 046 153 2 Pipe _ 322792 001 1 0 0 1 019 047 156 3 Pipe _ 322792 002 1 0 0 1 020 048 158 4 Pipe _ 322791 002 1 0 0 1 021 049 164 6 Pipe _ 322790 001 1 0 0 1 025 053 156 2 Pipe 2 Pipe 322792 001 1 0 0...

Страница 11: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 11 www trioniaq com 300 CFM Outline Drawing with Inlet Flange or Pipe 424399...

Страница 12: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 12 www trioniaq com 300 CFM Outline Drawing with Inlet Outlet Flange or Pipe 424398...

Страница 13: ...tor Part Number Flame Arrestor Power Supply 120 240 VAC VAC 439057 063 355 8 Flange 8 Flange 322791 003 1 0 439057 064 355 8 Flange 8 Flange 322791 003 0 1 600 CFM PARTS NOTE 1 The part number for the...

Страница 14: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 14 www trioniaq com 600 CFM Outline Drawing 429436...

Страница 15: ...ONIZER BLK WHT IONIZER BLK GRN WHT 120V 50 60 HZ 1 LINE GROUND NEUTRAL BLK RED LED 120VAC CATHODE ANODE NEUT GRD POWER SUPPLY RED BLACK BLK WHT BOX MOUNTING RECEPTACLE PRIMARY LEAD AND PLUG ASSY ENCLO...

Страница 16: ...nd 300 CFM 268678 003 Primary Plug and Receptacle Assembly 240 VAC Input Voltage 150 and 300 CFM 1 268678 002 Primary Plug and Receptacle Assembly 120 VAC Input Voltage 600 CFM 268678 004 Primary Plug...

Страница 17: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 17 www trioniaq com V DIAGRAM 3 6 5 1 4 2...

Страница 18: ...Form No 61 0184 Rev 10 16 TRION 2016 All Rights Reserved TRION 101 McNeill Rd Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioniaq com customerservice trioniaq com...

Отзывы: