Model 38 Series
I n s t a l l a t i o n , O p e r a t i o n , & M a i n t e n a n c e M a n u a l
6
www.trioniaq.com
3. Increase in particulate concentration above unit
rating. Reduce concentrations.
4. Low secondary voltage. The ionizer voltage should
be -13 KVDC +/- 500 VDC. The collector voltage
should be -6.5 KVDC +/- 500 VDC. The ionizer
current should be between 0.5 and 1.5 mA.
5. Loose or faulty high voltage connection between
power supply and ionizer-collector elements. Check
secondary wiring from power supply to high voltage
contact springs. Check high voltage contacts to be
sure they are contacting both ionizer and collector.
VI. RECOMMENDED SPARE PARTS
ITEM
DESCRIPTION
PART NO.
QTY SUGGESTED
A
All 120 VAC Input Power Supply
267232-120
1
All 240 VAC Input Power Supply
267232-240
B
LED Assembly
241101-020
1
C
Spring Contact
221952-001
1