Lengths less than 1,000’ [305 m] can be supplied with a factory applied fitting (right–hand fitting)
on one end, or the lengths can be cut from a continuous reel and a field applied fitting placed on
both ends
Cable Splices
There are three types of cable splices that can be utilized.
•
Factory applied fittings with a turnbuckle (1” hardware only).
•
Field applied fittings with a turnbuckle (3/4” and 1” hardware).
•
Torpedo fitting.
Factory Applied Fittings with Turnbuckle
1. To assemble a factory applied splice, one of the two cable ends must have a fitting with
right-handed threads and the other cable must have a fitting with left-handed threads.
Place a mark 1 1/2” [38 mm] from the end of each fitting. On one of the threaded end
place a turnbuckle (PN-5826). Attached the turnbuckle where it is held on the threaded
end by only a couple of threads.
2. Place the other threaded end in the turnbuckle.
3. While rotating the turnbuckle, prevent the two threaded ends from rotating. Rotate the
turnbuckle until both threaded ends are into the turnbuckle beyond the 1 1/2” [38 mm]
mark. See Figure 6 for the complete assembly.
Field Applied Fittings with Turnbuckle
There are two situations where a field applied fitting will be used: either when a fitting is required
to complete an assembly; or when no factory applied fittings are used and field applied fittings are
needed to make all of the cable connections. See Figure 6a for a 1” Cable Splice (PN-5633G)
and Figure 6b for 3/4” Cable Splice (PN-5698G).