Set Up Guide | Floor Scale
8
c. Carefully insert the bare end of the wire
into the terminal opening.
d. While holding the wire in position,
tighten down the terminal screw. After
tightening, gently pull the wire to make
sure it’s secure.
e. Repeat the process for the remaining
wires.
WHEN INSERTING THE WIRE INTO THE
TERMINAL CLAMP, MAKE SURE THE CLAMP SECURES
THE BARE WIRE AND NOT THE COLORED INSULATION
OF THE WIRE.
IF THE BARE END OF THE WIRE IS NOT
PROPERLY SECURED, THE SCALE WILL NOT
OPERATE CORRECTLY! THIS WILL BE THE MOST
LIKELY CAUSE OF ANY PROBLEM YOU MAY HAVE
WHEN USING THE SCALE FOR THE FIRST TIME.
4. Once all the wires are secure, pull out any
excess slack in the cable through the liquid
tight fitting.
5. Tighten the liquid tight fitting nut to secure
the cable to prevent moisture from entering
the junction box.
6. Replace the junction box faceplate.
7. Replace the junction box access plate.
8. Connect the AC adapter to the indicator and
then to the wall outlet. If the unit has and AC
power cord, connect it to the wall outlet.