background image

                   

Set Up Guide | Floor Scale                                

 

 

 
 
foot downward until solid contact is made 
with the floor.

 

4.  When all feet are in contact with the floor, 

check the platform with a level to make sure 
it is within 

¼

 inch of level.  

5.  MAKE CERTAIN that the platform does not 

rock from corner to corner. Any amount of 
rocking will result in inaccurate weighing.

 

6.  If desired, tighten the jam-nut against the 

bottom of the load cell to lock the foot into 
place. 

 

Содержание TSM Series

Страница 1: ...w trinerscale com SUG Version 2 0_02 15 13 Guide for setting up the Triner TSM Low Profile Floor Scale Platform and connecting to any of the following digital indicators TS 700 SS 7600e DIGITAL INDICA...

Страница 2: ...without notice For Parts Service and Support Look for a Service Sticker on ALL sides of the Digital Indicator If a service sticker is present contact the servicing dealer The servicing dealer is usua...

Страница 3: ...Installing and Leveling the Platform 4 Connecting the Digital Indicator to the Weighing Platform 6 Standard TSM Series Indicators 6 Connecting a TS 700 MS Indicator 6 Connecting a TS 700 SS Indicator...

Страница 4: ...nclosed in a watertight junction box The junction box is accessible from the top of the scale for ease of service The platform utilizes precision ball and cup style adjustable leveling feet designed t...

Страница 5: ...ration of the scale digital indicator please see the User s Guide that is included with the digital indicator BE SURE TO UNPACK ALL ITEMS IN THE DIGITAL INDICATOR SHIPPING CARTON The scale comes facto...

Страница 6: ...ERFACE CABLE DAMAGE BE SURE TO PROTECT THE CABLE AND KEEP IT OUT OF HARM S WAY For best results the scale should be installed on smooth level concrete Installing the scale on dirt gravel or asphalt is...

Страница 7: ...ct with the floor check the platform with a level to make sure it is within inch of level 5 MAKE CERTAIN that the platform does not rock from corner to corner Any amount of rocking will result in inac...

Страница 8: ...NECTING CABLE WILL BE FOUND IN ONE OF TWO LOCATIONS DEPENDING ON THE MODEL OF INDICATOR PURCHASED IT WILL BE IN THE SHIPPING CARTON WITH THE INDICATOR OR BUNDLED INSIDE THE JUNCTION BOX AREA INSIDE TH...

Страница 9: ...is ready for use CONNECTING A TS 700 SS INDICATOR OR CONNECTING A 7600E INDICATOR The interface cable is pre wired to the digital indicator and requires connecting the five wire leads into the weighin...

Страница 10: ...E BARE END OF THE WIRE IS NOT PROPERLY SECURED THE SCALE WILL NOT OPERATE CORRECTLY THIS WILL BE THE MOST LIKELY CAUSE OF ANY PROBLEM YOU MAY HAVE WHEN USING THE SCALE FOR THE FIRST TIME 4 Once all th...

Страница 11: ...dicator on After the power up sequence the display should indicate Zero If it does not press the ZERO key 10 When the digital indicator displays 0 the scale is ready for use Fig 3 0 JBox Wiring Diagra...

Страница 12: ...perly repair cable Interface Cable wiring problem Check connections inside junction box and at indicator Display stays at Zero Scale will not weigh anything Item may be too light for scale resolution...

Страница 13: ...evel the scale by properly adjusting the leveling feet Load cell connections faulty Check load cell connections inside junction box Load cell or load cell cable damage Inspect load cell cables Test an...

Страница 14: ...Zero the indicator according to the indicator manual Platform binding Provide adequate clearance for free platform movement Make sure a ramp s is not touching the scale Remove any debris under and aro...

Страница 15: ...platform 3 Make sure the scale is level Adjust the leveling feet if required to make sure all four feet are in contact with the floor 4 Periodic Calibration Notes a The scale is shipped factory calibr...

Страница 16: ...oor Scale 14 g Calibrating the scale with anything other than industry standard test weights is not recommended or reliable Refer to your own quality standards to determine what kind of test weight is...

Страница 17: ...ly with signal trim summing card JBOX 1 2 20 precision ball and cup leveling foot FOOT07 2 5k 2 500 lb Sheerbeam load cell LC002 5k 5 000 lb Sheerbeam load cell LC004 Load cell Bolt M12 x 1 75 x 50mm...

Страница 18: ...responsible for warranty service should the Triner Scale label or logo or the serial number be removed or the product fail to be properly maintained or fail to function properly as a result of misuse...

Отзывы: