1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008
Due to the rate of flow of oils across different materials there is always a potential to
build up a static charge. Static discharge can cause an explosion if near, or around,
open flammable fluids. Bonding and ground safety procedures must be used when
operating in hazardous duty environments or when there is a danger of static discharge.
See National Fire Protection Code 77 for proper grounding and bonding procedures. It
is the responsibility of the operator to properly inspect and ground equipment before
use.
Design Information:
3
6933 Pneumatic High-Viscosity Filtration Cart System
Type: Industrial Grade Gear Pump
Max Temperature: 200°F/93°C
Suction/ Discharge line: 1” Synthetic Rubber Hydraulic Hose
Filter Type: Spin-on
Filter Head By-Pass Pressure: 43 psi differential
Upper Filters Media: 10 Micron absolute Beta>200
Lower Filters Media: 10 Micron Nominal Water
Replace Element @: 40 psi differential
Max Viscosity: 7500 SUS (1600 cSt)
Max Flow Rate: 3.0 GPM
Max Pneumatic Motor Speed: 3000 rpm
Max Supply Air Pressure: 120psi
Preset FRL Air Pressure: 100psi
Pump Relief: 105 psi
Suction / Lift: 20 ft
Filter Collapse Rating: 80 psi differential
Maximum Filter Operating Pressure: 120 psi
36934 Pneumatic High-Viscosity Portable Hand-Held System
Type: Industrial Grade Gear Pump
Max Temperature: 200°F/93°C
Suction line: 3/4” Synthetic Rubber Hydraulic Hose
Discharge line: 1” Synthetic Rubber Hydraulic Hose
Filter Type: Spin-on
Filter Head By-Pass Pressure: 43 psi differential
Filter 1 Media: 10 Micron absolute Beta>200
Filter 2 Media: 10 Micron Nominal Water
Replace Element @: 40 psi differential
Max Viscosity: 7500 SUS (1600 cSt)
Max Flow Rate: 1.0 GPM
Max Pneumatic Motor Speed: 3000 rpm
Max Supply Air Pressure: 120psi
Preset FRL Air Pressure: 100psi
Suction / Lift: 20 ft
Pump Relief: 85 psi
Filter Differential Collapse Rating: 80 psi
Maximum Filter Operating Pressure: 250 psi